Transient heat transfer characteristics and multi-objective optimization of HTGR thermal insulation cavity based on an iterative thermal network

The thermal protection design of the internal insulation cavity is crucial for the drive motor of a High-Temperature Gas-Cooled Reactor (HTGR) under extreme thermal shocks. Nonetheless, the insulation flange, as the core component of this cavity, exhibits an inherent physical constraint between its steady-state thermal insulation and transient thermal shock resistance, making it difficult to satisfy both protection requirements through single-dimensional design. Moreover, the traditional three-dimensional Finite Volume Method (FVM) entails prohibitive computational costs during multi-constraint structural optimization, failing to meet the demands of large-scale parametric design. Given this issue, with the HTGR insulation cavity as the research object, a multi-objective collaborative optimization method is established based on the Transient Thermal Network Model (TNM) and extreme value normalization theory. First, a TNM reduced-order model of the flange and insulation components is constructed using the lumped parameter method, followed by the validation of its accuracy in transient heat transfer calculations against limited FVM simulations. On this basis, the steady-state total temperature difference and the maximum transient temperature change rate are extracted as evaluation indicators. Through extreme value normalization, the dimensional impact is eliminated to construct a comprehensive evaluation objective function that considers both steady-state and transient protection performance. This model enables parametric optimization of the axial height of the insulation ring under an equal-volume constraint, revealing the nonlinear influence law of structural dimensions on the comprehensive evaluation index. The results demonstrate that the comprehensive evaluation index achieves its optimal value when the axial height of the insulation ring is near 93.2 mm. At this point, the comprehensive thermal protection performance of the flange achieves an optimal thermal balance. The maximum error between this optimal solution and the FVM calculation results is 6.14% according to cross-validation. This study effectively reduces the computational cost of complex heat transfer processes. The established modeling and optimization framework provides methodological support for the design of HTGR thermal protection structures while exhibiting significant theoretical value and broad engineering applicability. It can be widely applied to other multi-component equipment featuring complex geometries and multi-dimensional heat transfer coupling that are suitable for efficient reduced-order thermal analysis using the thermal network model.

Authors

Institutions

Publication Details

Journal
Case Studies in Thermal Engineering
Published
2026-11-19
DOI
https://doi.org/10.1016/j.csite.2026.108731
Primary Topic
Nuclear Engineering Thermal-Hydraulics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Transient heat transfer characteristics and multi-objective optimization of HTGR thermal insulation cavity based on an iterative thermal network

Bowen Xi, Xiao Xu, Zihao Zhang, Xiangyang Han et al.
Case Studies in Thermal Engineering
Nuclear Engineering Thermal-Hydraulics
article

Transient heat transfer characteristics and multi-objective optimization of HTGR thermal insulation cavity based on an iterative thermal network

Bowen Xi, Xiao Xu, Zihao Zhang, Xiangyang Han, Zhao Wang
article en

Abstract

The thermal protection design of the internal insulation cavity is crucial for the drive motor of a High-Temperature Gas-Cooled Reactor (HTGR) under extreme thermal shocks. Nonetheless, the insulation flange, as the core component of this cavity, exhibits an inherent physical constraint between its steady-state thermal insulation and transient thermal shock resistance, making it difficult to satisfy both protection requirements through single-dimensional design. Moreover, the traditional three-dimensional Finite Volume Method (FVM) entails prohibitive computational costs during multi-constraint structural optimization, failing to meet the demands of large-scale parametric design. Given this issue, with the HTGR insulation cavity as the research object, a multi-objective collaborative optimization method is established based on the Transient Thermal Network Model (TNM) and extreme value normalization theory. First, a TNM reduced-order model of the flange and insulation components is constructed using the lumped parameter method, followed by the validation of its accuracy in transient heat transfer calculations against limited FVM simulations. On this basis, the steady-state total temperature difference and the maximum transient temperature change rate are extracted as evaluation indicators. Through extreme value normalization, the dimensional impact is eliminated to construct a comprehensive evaluation objective function that considers both steady-state and transient protection performance. This model enables parametric optimization of the axial height of the insulation ring under an equal-volume constraint, revealing the nonlinear influence law of structural dimensions on the comprehensive evaluation index. The results demonstrate that the comprehensive evaluation index achieves its optimal value when the axial height of the insulation ring is near 93.2 mm. At this point, the comprehensive thermal protection performance of the flange achieves an optimal thermal balance. The maximum error between this optimal solution and the FVM calculation results is 6.14% according to cross-validation. This study effectively reduces the computational cost of complex heat transfer processes. The established modeling and optimization framework provides methodological support for the design of HTGR thermal protection structures while exhibiting significant theoretical value and broad engineering applicability. It can be widely applied to other multi-component equipment featuring complex geometries and multi-dimensional heat transfer coupling that are suitable for efficient reduced-order thermal analysis using the thermal network model.

Case Studies in Thermal EngineeringVol. 88
Harbin University of Science and Technology (CN)
Nuclear Engineering Thermal-Hydraulics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon