Multi-Objective Solar–Wind Portfolio Optimization for Energy Yield and Low-Output Persistence: A Climate-Informed Assessment in Eastern Anatolia, Türkiye

Renewable capacity planning must consider not only mean energy yield but also the frequency and persistence of low-generation periods. The main contribution of this study is a province-specific, three-objective solar–wind portfolio optimization framework that treats energy yield, low-output frequency and low-output persistence jointly and tests the selected portfolios on independent weather years. The framework was applied to 14 provinces of Eastern Anatolia, Türkiye, using hourly ERA5 and ERA5-Land data for 2020–2024 to optimize the photovoltaic share and spatial wind capacity allocation against the mean capacity factor, the percentage of hours below 0.05 and the longest consecutive low-output event. Across 840 independent runs, the non-dominated sorting genetic algorithm III (NSGA-III) outperformed the decomposition-based MOEA/D in 12 of 14 provinces. In the independent 2023–2024 test period, Maximum Energy portfolios, solar-only in all provinces, achieved a mean capacity factor of 0.177, versus 0.137 and 0.110 for Balanced and Frequency Priority portfolios, whereas low-output frequency fell only from 54.7% to 51.6% and 49.7%. Fewer low-output hours did not shorten persistent events: the mean longest event increased from 20.5 h to 29.5 h, and the frequency ranking reversed at a threshold of 0.10. Bias correction reduced the mean absolute wind speed bias of ten CMIP6 models from 0.70 to 0.04 m s−1. An indicative cost screening showed that adding wind at the reanalysis-derived capacity factors raised the levelized cost from about 41 to 63–88 USD MWh−1. Because a 3-percentage-point reduction in low-output hours cost 22% of the energy yield, yield, low-output frequency and event persistence should be assessed jointly under explicit low-output definitions rather than inferred from mean output.

Authors

Institutions

Publication Details

Journal
Sustainability
Published
2026-11-19
DOI
https://doi.org/10.3390/su182211806
Primary Topic
Integrated Energy Systems Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Multi-Objective Solar–Wind Portfolio Optimization for Energy Yield and Low-Output Persistence: A Climate-Informed Assessment in Eastern Anatolia, Türkiye

Ahmet Aktürk, Seda Türk
Sustainability
Integrated Energy Systems Optimization
article

Multi-Objective Solar–Wind Portfolio Optimization for Energy Yield and Low-Output Persistence: A Climate-Informed Assessment in Eastern Anatolia, Türkiye

Ahmet Aktürk, Seda Türk
article en

Abstract

Renewable capacity planning must consider not only mean energy yield but also the frequency and persistence of low-generation periods. The main contribution of this study is a province-specific, three-objective solar–wind portfolio optimization framework that treats energy yield, low-output frequency and low-output persistence jointly and tests the selected portfolios on independent weather years. The framework was applied to 14 provinces of Eastern Anatolia, Türkiye, using hourly ERA5 and ERA5-Land data for 2020–2024 to optimize the photovoltaic share and spatial wind capacity allocation against the mean capacity factor, the percentage of hours below 0.05 and the longest consecutive low-output event. Across 840 independent runs, the non-dominated sorting genetic algorithm III (NSGA-III) outperformed the decomposition-based MOEA/D in 12 of 14 provinces. In the independent 2023–2024 test period, Maximum Energy portfolios, solar-only in all provinces, achieved a mean capacity factor of 0.177, versus 0.137 and 0.110 for Balanced and Frequency Priority portfolios, whereas low-output frequency fell only from 54.7% to 51.6% and 49.7%. Fewer low-output hours did not shorten persistent events: the mean longest event increased from 20.5 h to 29.5 h, and the frequency ranking reversed at a threshold of 0.10. Bias correction reduced the mean absolute wind speed bias of ten CMIP6 models from 0.70 to 0.04 m s−1. An indicative cost screening showed that adding wind at the reanalysis-derived capacity factors raised the levelized cost from about 41 to 63–88 USD MWh−1. Because a 3-percentage-point reduction in low-output hours cost 22% of the energy yield, yield, low-output frequency and event persistence should be assessed jointly under explicit low-output definitions rather than inferred from mean output.

SustainabilityVol. 18(22)
Iğdır Üniversitesi (TR)
Integrated Energy Systems Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon