Variability and controls of wildfire smoke infiltration in school buildings

Wildfire smoke causes extreme fine particulate matter (PM 2.5 ) pollution in North America. Although people are advised to remain indoors, the protection provided by schools remains poorly constrained. We analyzed hourly paired indoor and outdoor PM 2.5 measurements from calibrated sensors at five K–12 schools in New York’s Capital Region from September 2024 to December 2025. Satellite smoke observations and network PM 2.5 measurements were used to classify pollution regimes, and an emission-screening and mass-balance framework was applied to isolate outdoor-derived particles and estimate infiltration factors ( F inf ). On wildfire days, mean indoor PM 2.5 reached 10.09 μg m -3 , compared with 3.71 μg m -3 on non-wildfire days, representing a 2.72-fold increase, primarily driven by elevated outdoor PM 2.5 , while F inf remained high (0.69–0.95 across schools) and was modestly higher than under clean background conditions (0.65–0.92). F inf varied with pollution regime, occupancy-related operation, and temperature. During non-wildfire periods, mean F inf increased with outdoor temperature before reaching a plateau around 20–25 °C, remaining at 0.77–0.78 at higher temperatures. F inf was also higher on school days and during instructional hours, highlighting the influence of building operation on indoor–outdoor particle coupling. Mass-balance simulations showed that increasing indoor particle removal could substantially reduce indoor PM 2.5 and weaken indoor–outdoor coupling, although improvement varied across buildings. These findings demonstrate that wildfire PM 2.5 can penetrate school buildings and that protection varies with temperature, occupancy-related operation, and building-specific conditions, supporting building-specific strategies to reduce indoor smoke exposure.

Authors

Institutions

Publication Details

Journal
npj Clean Air
Published
2026-11-19
DOI
https://doi.org/10.1038/s44407-026-00116-y
Primary Topic
Indoor Air Quality and Microbial Exposure
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Variability and controls of wildfire smoke infiltration in school buildings

Minghao Qiu, Lu Li, Jie Zhang, Xiaoliang Wang et al.
npj Clean Air
Indoor Air Quality and Microbial Exposure
article

Variability and controls of wildfire smoke infiltration in school buildings

Minghao Qiu, Lu Li, Jie Zhang, Xiaoliang Wang, Aynul Bari, Yuhang Guo
article en

Abstract

Wildfire smoke causes extreme fine particulate matter (PM 2.5 ) pollution in North America. Although people are advised to remain indoors, the protection provided by schools remains poorly constrained. We analyzed hourly paired indoor and outdoor PM 2.5 measurements from calibrated sensors at five K–12 schools in New York’s Capital Region from September 2024 to December 2025. Satellite smoke observations and network PM 2.5 measurements were used to classify pollution regimes, and an emission-screening and mass-balance framework was applied to isolate outdoor-derived particles and estimate infiltration factors ( F inf ). On wildfire days, mean indoor PM 2.5 reached 10.09 μg m -3 , compared with 3.71 μg m -3 on non-wildfire days, representing a 2.72-fold increase, primarily driven by elevated outdoor PM 2.5 , while F inf remained high (0.69–0.95 across schools) and was modestly higher than under clean background conditions (0.65–0.92). F inf varied with pollution regime, occupancy-related operation, and temperature. During non-wildfire periods, mean F inf increased with outdoor temperature before reaching a plateau around 20–25 °C, remaining at 0.77–0.78 at higher temperatures. F inf was also higher on school days and during instructional hours, highlighting the influence of building operation on indoor–outdoor particle coupling. Mass-balance simulations showed that increasing indoor particle removal could substantially reduce indoor PM 2.5 and weaken indoor–outdoor coupling, although improvement varied across buildings. These findings demonstrate that wildfire PM 2.5 can penetrate school buildings and that protection varies with temperature, occupancy-related operation, and building-specific conditions, supporting building-specific strategies to reduce indoor smoke exposure.

npj Clean AirVol. 2(1)
State University of New York (US), University at Albany, State University of New York (US), Stony Brook University (US), Desert Research Institute (US)
Indoor Air Quality and Microbial Exposure
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon