Breakdown Characteristics and Mechanisms of Compressed N2/O2 Mixture Gas With and Without a Teflon Dielectric: Implications for Electrical Arc Ignition Sources

Electrical arcs resulting from gas breakdown can act as potential ignition sources for electrical fires in high-voltage electrical equipment. However, the microscopic processes leading to electrical arc formation as a potential ignition source remain insufficiently understood, particularly the different effects of gas pressure and solid dielectrics on gas breakdown and surface flashover. This study investigates the AC breakdown characteristics of N2/O2 mixed gas under different gas pressures in electrode configurations with and without a PTFE (Teflon) dielectric to clarify the effects of gas pressure and the presence of Teflon on breakdown voltage and surface flashover voltage. The breakdown voltages are measured, and their pressure dependence is quantitatively evaluated using linear regression analysis. The breakdown voltages increase with gas pressure in both configurations, but the pressure dependence differs significantly. The regression slopes are 59.143 kV/MPa without Teflon and 16.400 kV/MPa with Teflon, indicating that the pressure dependence without Teflon is approximately 3.6 times as large as that with Teflon. The fitted regression lines intersected at approximately 0.400 MPa, which is consistent with the measured reversal in breakdown voltage and surface flashover voltage between 0.3 and 0.4 MPa. The proposed breakdown mechanisms provide a possible explanation for the different pressure dependences and voltage reversal based on electron generation and streamer development in the two electrode configurations. These findings provide fundamental information on the electrical breakdown processes preceding potential arc formation and may contribute to future studies on electrical ignition sources in air-insulated electrical equipment.

Authors

Institutions

Publication Details

Journal
Fire
Published
2026-11-19
DOI
https://doi.org/10.3390/fire9110526
Primary Topic
Vacuum and Plasma Arcs
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Breakdown Characteristics and Mechanisms of Compressed N2/O2 Mixture Gas With and Without a Teflon Dielectric: Implications for Electrical Arc Ignition Sources

Young‐Cheon Yu, Seung‐Wook Jee, Dong‐Young Lim, Guk Hoe Kim
Fire
Vacuum and Plasma Arcs
article

Breakdown Characteristics and Mechanisms of Compressed N2/O2 Mixture Gas With and Without a Teflon Dielectric: Implications for Electrical Arc Ignition Sources

Young‐Cheon Yu, Seung‐Wook Jee, Dong‐Young Lim, Guk Hoe Kim
article en

Abstract

Electrical arcs resulting from gas breakdown can act as potential ignition sources for electrical fires in high-voltage electrical equipment. However, the microscopic processes leading to electrical arc formation as a potential ignition source remain insufficiently understood, particularly the different effects of gas pressure and solid dielectrics on gas breakdown and surface flashover. This study investigates the AC breakdown characteristics of N2/O2 mixed gas under different gas pressures in electrode configurations with and without a PTFE (Teflon) dielectric to clarify the effects of gas pressure and the presence of Teflon on breakdown voltage and surface flashover voltage. The breakdown voltages are measured, and their pressure dependence is quantitatively evaluated using linear regression analysis. The breakdown voltages increase with gas pressure in both configurations, but the pressure dependence differs significantly. The regression slopes are 59.143 kV/MPa without Teflon and 16.400 kV/MPa with Teflon, indicating that the pressure dependence without Teflon is approximately 3.6 times as large as that with Teflon. The fitted regression lines intersected at approximately 0.400 MPa, which is consistent with the measured reversal in breakdown voltage and surface flashover voltage between 0.3 and 0.4 MPa. The proposed breakdown mechanisms provide a possible explanation for the different pressure dependences and voltage reversal based on electron generation and streamer development in the two electrode configurations. These findings provide fundamental information on the electrical breakdown processes preceding potential arc formation and may contribute to future studies on electrical ignition sources in air-insulated electrical equipment.

FireVol. 9(11)
Kangwon National University (KR), Korea Health Industry Development Institute (KR), Osong Medical Innovation Foundation (KR)
Vacuum and Plasma Arcs
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon