Condensation Heat Transfer of Carbon Dioxide in a Horizontal 2 mm Tube

Condensation heat transfer in small-diameter tubes is important for the design of compact CO2 condensers. In this study, CO2 condensation heat transfer in a horizontal smooth tube with an inner diameter of 2 mm was investigated experimentally and numerically at saturation pressures of 5.5–6.5 MPa. The experimental effective mean condensation heat transfer coefficients were determined using the Wilson plot method and ranged from 4.47 to 6.77 kW m−2 K−1, increasing with mass flux at each saturation pressure. Three-dimensional volume-of-fluid simulations were conducted at mass fluxes of 100–500 kg m−2 s−1. The numerical results illustrate the axial and circumferential variations in condensation heat transfer associated with gravitational effects and condensate film development. At 6.0 MPa, the numerical mean heat transfer coefficients were approximately 20–27% higher than the experimental values, while both the experimental and numerical results showed an increasing trend with mass flux. Furthermore, an empirical heat transfer correlation was developed using 469 literature and numerical records, yielding a mean absolute relative error of 22.5%, with 73.6% of the data falling within ±30% deviation. The proposed correlation provides a basis for preliminary condensation heat transfer estimation within the investigated parameter ranges.

Authors

Institutions

Publication Details

Journal
Energies
Published
2026-11-19
DOI
https://doi.org/10.3390/en19225593
Primary Topic
Heat Transfer and Boiling Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Condensation Heat Transfer of Carbon Dioxide in a Horizontal 2 mm Tube

Dianle Wang, Yihao Jing, Junxiang Zhao
Energies
Heat Transfer and Boiling Studies
article

Condensation Heat Transfer of Carbon Dioxide in a Horizontal 2 mm Tube

Dianle Wang, Yihao Jing, Junxiang Zhao
article en

Abstract

Condensation heat transfer in small-diameter tubes is important for the design of compact CO2 condensers. In this study, CO2 condensation heat transfer in a horizontal smooth tube with an inner diameter of 2 mm was investigated experimentally and numerically at saturation pressures of 5.5–6.5 MPa. The experimental effective mean condensation heat transfer coefficients were determined using the Wilson plot method and ranged from 4.47 to 6.77 kW m−2 K−1, increasing with mass flux at each saturation pressure. Three-dimensional volume-of-fluid simulations were conducted at mass fluxes of 100–500 kg m−2 s−1. The numerical results illustrate the axial and circumferential variations in condensation heat transfer associated with gravitational effects and condensate film development. At 6.0 MPa, the numerical mean heat transfer coefficients were approximately 20–27% higher than the experimental values, while both the experimental and numerical results showed an increasing trend with mass flux. Furthermore, an empirical heat transfer correlation was developed using 469 literature and numerical records, yielding a mean absolute relative error of 22.5%, with 73.6% of the data falling within ±30% deviation. The proposed correlation provides a basis for preliminary condensation heat transfer estimation within the investigated parameter ranges.

EnergiesVol. 19(22)
Sichuan University (CN), Dongfang Electric Corporation (China) (CN), Nuclear Power Institute of China (CN)
Heat Transfer and Boiling Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon