Computer-Assisted C1 Pedicle Screw Fixation in the Treatment of Atlantoaxial Instability: Anatomical Considerations and Radiological Outcomes

Background C1 pedicle screw (CPS) fixation provides superior stability over C1 lateral mass screws (LMS) for atlantoaxial instability but is limited by anatomical variability and vascular risk. We propose a novel planning strategy that uses a patient-specific instrument (PSI) by 3D printing to improve the safety and accuracy of C1 CPS placement. Methods In this retrospective study, 22 patients underwent C1 CPS fixation using PSI between August 2015 and August 2025, with 44 screws implanted. Pedicles were classified according to the morphological classification proposed by Abhishek Srivastava et al. Screw trajectories were preoperatively planned, and PSIs were fabricated accordingly. Postoperative CT assessed screw placement accuracy using Gertzbein–Robbins (GR) grading. Results Twenty-two patients (9 males, 13 females; mean age 68.7 ± 13.1 years) were included. Morphological analysis of the C1 pedicles demonstrated a mean right-sided extramedullary height (EMH) of 3.81 ± 1.06 mm and intramedullary height (IMH) of 1.20 ± 1.05 mm, while the left-sided EMH and IMH were 3.92 ± 1.20 mm and 1.30 ± 1.11 mm, respectively. The 44 pedicles were classified as 16 Type 1A, 4 Type 1B, 1 Type 2, and 23 Type 3.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-20
DOI
https://doi.org/10.21203/rs.3.rs-11792206/v1
Primary Topic
Spinal Fractures and Fixation Techniques
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Computer-Assisted C1 Pedicle Screw Fixation in the Treatment of Atlantoaxial Instability: Anatomical Considerations and Radiological Outcomes

Chih-Ju Chang, Jing-Jing Fang, Kuan‐Yu Chen, Meng-Hsuan Hsieh
Research Square
Spinal Fractures and Fixation Techniques
preprint

Computer-Assisted C1 Pedicle Screw Fixation in the Treatment of Atlantoaxial Instability: Anatomical Considerations and Radiological Outcomes

Chih-Ju Chang, Jing-Jing Fang, Kuan‐Yu Chen, Meng-Hsuan Hsieh
preprint en

Abstract

Background C1 pedicle screw (CPS) fixation provides superior stability over C1 lateral mass screws (LMS) for atlantoaxial instability but is limited by anatomical variability and vascular risk. We propose a novel planning strategy that uses a patient-specific instrument (PSI) by 3D printing to improve the safety and accuracy of C1 CPS placement. Methods In this retrospective study, 22 patients underwent C1 CPS fixation using PSI between August 2015 and August 2025, with 44 screws implanted. Pedicles were classified according to the morphological classification proposed by Abhishek Srivastava et al. Screw trajectories were preoperatively planned, and PSIs were fabricated accordingly. Postoperative CT assessed screw placement accuracy using Gertzbein–Robbins (GR) grading. Results Twenty-two patients (9 males, 13 females; mean age 68.7 ± 13.1 years) were included. Morphological analysis of the C1 pedicles demonstrated a mean right-sided extramedullary height (EMH) of 3.81 ± 1.06 mm and intramedullary height (IMH) of 1.20 ± 1.05 mm, while the left-sided EMH and IMH were 3.92 ± 1.20 mm and 1.30 ± 1.11 mm, respectively. The 44 pedicles were classified as 16 Type 1A, 4 Type 1B, 1 Type 2, and 23 Type 3.

Research Square
Cathay General Hospital (TW), National Cheng Kung University (TW)
Spinal Fractures and Fixation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon