A brief self-report scale for screening heat illness risk in heat-exposed young men: development and multicentre validation in China

Background This study aimed to develop and validate a brief self-report scale, the Heat Illness Susceptibility Screening Scale (HISS), for population-level screening of heat illness risk among heat-exposed young men, and to evaluate its reliability, structural validity, and concurrent validity for identifying individuals at high risk of heat illness. Methods Guided by heat stress physiology and heat acclimation theory, the HISS was developed through a systematic process involving literature review, item generation, and Delphi expert consultation, yielding a 13-item scale across four dimensions. A multicentre, multiregional sampling strategy was employed to recruit 2,327 heat-exposed young men aged 20–30 years. Participants were allocated to three independent analytic datasets for exploratory factor analysis (EFA, n = 366), confirmatory factor analysis (CFA) and reliability analysis ( n = 383), and concurrent validity analysis ( n = 1,578). Analytical procedures included EFA, CFA, internal consistency assessment, and receiver operating characteristic (ROC) curve analysis. Results EFA extracted four factors that collectively accounted for 64.46% of the common variance. CFA demonstrated good model fit (χ 2 /df = 1.836, RMSEA = 0.047, CFI = 0.983, TLI = 0.977). The HISS exhibited good internal consistency, with an overall Cronbach’s α of 0.832 and subscale α values all exceeding 0.75. ROC analysis yielded an AUC of 0.804 (95% CI: 0.780–0.827) for identifying individuals at high risk of heat illness, with an optimal cutoff of 38.5 points. Conclusion The HISS demonstrated acceptable internal consistency, structural validity, and concurrent discriminative performance in heat-exposed young men. It may serve as a practical field-based screening tool for the early identification of individuals who may warrant further heat illness risk assessment in populations engaged in regular physical training in hot environments.

Authors

Institutions

Publication Details

Journal
Frontiers in Public Health
Published
2026-11-19
DOI
https://doi.org/10.3389/fpubh.2026.2010351
Primary Topic
Thermoregulation and physiological responses
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A brief self-report scale for screening heat illness risk in heat-exposed young men: development and multicentre validation in China

Lincui Zhong, Qingbo Zeng, 宋景春, Yuqing Qiu et al.
Frontiers in Public Health
Thermoregulation and physiological responses
article

A brief self-report scale for screening heat illness risk in heat-exposed young men: development and multicentre validation in China

Lincui Zhong, Qingbo Zeng, 宋景春, Yuqing Qiu, Qingwei Lin, Longping He, 黃清華
article en

Abstract

Background This study aimed to develop and validate a brief self-report scale, the Heat Illness Susceptibility Screening Scale (HISS), for population-level screening of heat illness risk among heat-exposed young men, and to evaluate its reliability, structural validity, and concurrent validity for identifying individuals at high risk of heat illness. Methods Guided by heat stress physiology and heat acclimation theory, the HISS was developed through a systematic process involving literature review, item generation, and Delphi expert consultation, yielding a 13-item scale across four dimensions. A multicentre, multiregional sampling strategy was employed to recruit 2,327 heat-exposed young men aged 20–30 years. Participants were allocated to three independent analytic datasets for exploratory factor analysis (EFA, n = 366), confirmatory factor analysis (CFA) and reliability analysis ( n = 383), and concurrent validity analysis ( n = 1,578). Analytical procedures included EFA, CFA, internal consistency assessment, and receiver operating characteristic (ROC) curve analysis. Results EFA extracted four factors that collectively accounted for 64.46% of the common variance. CFA demonstrated good model fit (χ 2 /df = 1.836, RMSEA = 0.047, CFI = 0.983, TLI = 0.977). The HISS exhibited good internal consistency, with an overall Cronbach’s α of 0.832 and subscale α values all exceeding 0.75. ROC analysis yielded an AUC of 0.804 (95% CI: 0.780–0.827) for identifying individuals at high risk of heat illness, with an optimal cutoff of 38.5 points. Conclusion The HISS demonstrated acceptable internal consistency, structural validity, and concurrent discriminative performance in heat-exposed young men. It may serve as a practical field-based screening tool for the early identification of individuals who may warrant further heat illness risk assessment in populations engaged in regular physical training in hot environments.

Frontiers in Public HealthVol. 14
Jiangxi University of Traditional Chinese Medicine (CN), Nanchang University (CN)
Thermoregulation and physiological responses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon