Never fully dark: presence-controlled LED lighting with a safe background level for plantrooms and rooftop plant, evaluated with UK data from 2022 to 2026

Plantrooms and rooftop plant areas are visited for a few hours a week, yet their lighting is usually either left on permanently or switched off, so that staff enter dark spaces where slips, trips and falls are likely. This paper examines presence-controlled LED lighting that never switches fully off but dims to a background level chosen to keep the 20 lx average that HSE guidance gives for the movement of people. A lumen-method design for a 150 m² reference plantroom and an annual energy model were built in a spreadsheet and priced with UK electricity prices and carbon factors for 2022 to 2026. With 5 hours of occupancy a week, the proposed control used 783 kWh a year, 88% less than always-on twin T8 fluorescent lighting and 71% less than always-on LED. Keeping the room at a 20% background level cost 659 kWh a year more than switching off. The annual saving against fluorescent lighting rose from £1,167 in 2022 to £1,371 in 2026, while the carbon saving fell by 32% as the grid decarbonised. For battery luminaires on roofs, sensor standby power rather than light dominated the energy budget.

Authors

Publication Details

Journal
Engineering Archive (engrXiv)
Published
2026-11-19
DOI
https://doi.org/10.31224/8848
Primary Topic
Building Energy and Comfort Optimization
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Never fully dark: presence-controlled LED lighting with a safe background level for plantrooms and rooftop plant, evaluated with UK data from 2022 to 2026

Naushad Ali
Engineering Archive (engrXiv)
Building Energy and Comfort Optimization
preprint

Never fully dark: presence-controlled LED lighting with a safe background level for plantrooms and rooftop plant, evaluated with UK data from 2022 to 2026

Naushad Ali
preprint en

Abstract

Plantrooms and rooftop plant areas are visited for a few hours a week, yet their lighting is usually either left on permanently or switched off, so that staff enter dark spaces where slips, trips and falls are likely. This paper examines presence-controlled LED lighting that never switches fully off but dims to a background level chosen to keep the 20 lx average that HSE guidance gives for the movement of people. A lumen-method design for a 150 m² reference plantroom and an annual energy model were built in a spreadsheet and priced with UK electricity prices and carbon factors for 2022 to 2026. With 5 hours of occupancy a week, the proposed control used 783 kWh a year, 88% less than always-on twin T8 fluorescent lighting and 71% less than always-on LED. Keeping the room at a 20% background level cost 659 kWh a year more than switching off. The annual saving against fluorescent lighting rose from £1,167 in 2022 to £1,371 in 2026, while the carbon saving fell by 32% as the grid decarbonised. For battery luminaires on roofs, sensor standby power rather than light dominated the energy budget.

Engineering Archive (engrXiv)
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon