Optimal Coordination of Multiple FACTS Devices for Voltage Stability Enhancement in the Nigerian 330 kV Transmission Network

The performance of the Nigerian 330 kV transmission network is increasingly undermined by line congestion, voltage instability, inadequate reactive power compensation and elevated technical losses. This stems mainly from persistent growth in electricity demand amid inadequate expansion of transmission facilities.The resulting system is characterized by inefficient power transmission, inadequate voltage profiles, and recurrent grid instability, thereby compromising the reliability and security of electricity supply. Flexible AC Transmission System (FACTS) devices provide an effective approach to enhancing power-system performance through the dynamic control and regulation of key transmission parameters.Although previous studies have primarily focused on the application of individual FACTS devices, limited attention has been devoted to the coordinated deployment of multiple FACTS controllers for enhancing the performance of the Nigerian transmission system.This study presents an optimally coordinated application of UPFC, STATCOM, and TCSC for voltage stability improvement in the Nigerian 330 kV interconnected transmission system.The transmission system is comprehensively modeled in ETAP, while Newton–Raphson load-flow analysis is employed to evaluate its performance under both uncompensated and FACTS-compensated operating conditions. The performance of the coordinated control strategy is evaluated based on its ability to improve voltage profiles, reduce active and reactive power losses, alleviate transmission congestion, and enhance the available transfer capability of the network. Results obtained from simulations indicate that multi-FACTS coordination provides better performance than single FACTS compensation, with notable improvements in voltage stability, reduction in transmission losses, enhancement of power transfer capability, and operational reliability of the Nigerian transmission network. This study provides practical recommendations for transmission planners and utility operators to optimize FACTS placement for enhanced resilience, efficiency, and long-term sustainability of the Nigerian transmission infrastructure.

Authors

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-19
DOI
https://doi.org/10.5281/zenodo.24359080
Primary Topic
Power System Optimization and Stability
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Optimal Coordination of Multiple FACTS Devices for Voltage Stability Enhancement in the Nigerian 330 kV Transmission Network

C. O Omeje, Peletiri J. D
Zenodo (CERN European Organization for Nuclear Research)
Power System Optimization and Stability
article

Optimal Coordination of Multiple FACTS Devices for Voltage Stability Enhancement in the Nigerian 330 kV Transmission Network

C. O Omeje, Peletiri J. D
article en

Abstract

The performance of the Nigerian 330 kV transmission network is increasingly undermined by line congestion, voltage instability, inadequate reactive power compensation and elevated technical losses. This stems mainly from persistent growth in electricity demand amid inadequate expansion of transmission facilities.The resulting system is characterized by inefficient power transmission, inadequate voltage profiles, and recurrent grid instability, thereby compromising the reliability and security of electricity supply. Flexible AC Transmission System (FACTS) devices provide an effective approach to enhancing power-system performance through the dynamic control and regulation of key transmission parameters.Although previous studies have primarily focused on the application of individual FACTS devices, limited attention has been devoted to the coordinated deployment of multiple FACTS controllers for enhancing the performance of the Nigerian transmission system.This study presents an optimally coordinated application of UPFC, STATCOM, and TCSC for voltage stability improvement in the Nigerian 330 kV interconnected transmission system.The transmission system is comprehensively modeled in ETAP, while Newton–Raphson load-flow analysis is employed to evaluate its performance under both uncompensated and FACTS-compensated operating conditions. The performance of the coordinated control strategy is evaluated based on its ability to improve voltage profiles, reduce active and reactive power losses, alleviate transmission congestion, and enhance the available transfer capability of the network. Results obtained from simulations indicate that multi-FACTS coordination provides better performance than single FACTS compensation, with notable improvements in voltage stability, reduction in transmission losses, enhancement of power transfer capability, and operational reliability of the Nigerian transmission network. This study provides practical recommendations for transmission planners and utility operators to optimize FACTS placement for enhanced resilience, efficiency, and long-term sustainability of the Nigerian transmission infrastructure.

Zenodo (CERN European Organization for Nuclear Research)
University of Port Harcourt (NG)
Power System Optimization and Stability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon