Spatiotemporal dynamic lightning damage risk assessment for high-altitude distribution lines considering seasonal surface evolution and time-varying lightning withstand capability

The existing lightning risk assessment methods for distribution lines are usually based on lightning monitoring statistical data, and consider terrain conditions and key lightning resistance parameters as quasi-static variables. In high-altitude areas, there is a significant seasonal variation in environmental factors, and the deterioration of insulation performance differs greatly from that in plain areas. The risk assessment results of lightning damage to distribution lines are somewhat different from the actual situation. To address this problem, a spatiotemporal dynamic lightning risk assessment method is proposed for high-altitude distribution lines. First, static topographic information is combined with time-varying hydrological, vegetation, meteorological, freeze–thaw, and aeolian features to characterize the monthly evolution of surface environmental states along distribution corridors. Second, environment-dependent dynamic models of insulator degradation and grounding resistance are established, and the actual lightning impulse withstand capability of line equipment is corrected accordingly. Furthermore, historical lightning-location observations are used to learn a terrain–climate coupled correction factor for lightning aggregation, thereby characterizing the temporal variation of local lightning exposure. Finally, the time-varying surface environment, lightning characteristics, and equipment withstand capability are coupled to obtain monthly tower-level lightning risk. The proposed method is applied to a 10 kV distribution line in Huangnan Tibetan Autonomous Prefecture. The results showed that the consistency rate between the medium to high risk level determined by the proposed method and actual tripping accidents was about 92%, which was significantly higher than the traditional assessment based on lightning strike density. The proposed method can capture seasonal risk variations associated with changes in surface conditions, providing a basis for differentiated lightning protection and seasonal operation and maintenance of high-altitude distribution networks.

Authors

Institutions

Publication Details

Journal
Frontiers in Energy Research
Published
2026-11-19
DOI
https://doi.org/10.3389/fenrg.2026.1985671
Primary Topic
Lightning and Electromagnetic Phenomena
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Spatiotemporal dynamic lightning damage risk assessment for high-altitude distribution lines considering seasonal surface evolution and time-varying lightning withstand capability

Xiaoyan Liang, 岳雷, Xiaodong Deng, Qingchun Sa et al.
Frontiers in Energy Research
Lightning and Electromagnetic Phenomena
article

Spatiotemporal dynamic lightning damage risk assessment for high-altitude distribution lines considering seasonal surface evolution and time-varying lightning withstand capability

Xiaoyan Liang, 岳雷, Xiaodong Deng, Qingchun Sa, Shaoliang Zhang, Shuai Jin
article en

Abstract

The existing lightning risk assessment methods for distribution lines are usually based on lightning monitoring statistical data, and consider terrain conditions and key lightning resistance parameters as quasi-static variables. In high-altitude areas, there is a significant seasonal variation in environmental factors, and the deterioration of insulation performance differs greatly from that in plain areas. The risk assessment results of lightning damage to distribution lines are somewhat different from the actual situation. To address this problem, a spatiotemporal dynamic lightning risk assessment method is proposed for high-altitude distribution lines. First, static topographic information is combined with time-varying hydrological, vegetation, meteorological, freeze–thaw, and aeolian features to characterize the monthly evolution of surface environmental states along distribution corridors. Second, environment-dependent dynamic models of insulator degradation and grounding resistance are established, and the actual lightning impulse withstand capability of line equipment is corrected accordingly. Furthermore, historical lightning-location observations are used to learn a terrain–climate coupled correction factor for lightning aggregation, thereby characterizing the temporal variation of local lightning exposure. Finally, the time-varying surface environment, lightning characteristics, and equipment withstand capability are coupled to obtain monthly tower-level lightning risk. The proposed method is applied to a 10 kV distribution line in Huangnan Tibetan Autonomous Prefecture. The results showed that the consistency rate between the medium to high risk level determined by the proposed method and actual tripping accidents was about 92%, which was significantly higher than the traditional assessment based on lightning strike density. The proposed method can capture seasonal risk variations associated with changes in surface conditions, providing a basis for differentiated lightning protection and seasonal operation and maintenance of high-altitude distribution networks.

Frontiers in Energy ResearchVol. 14
State Grid Corporation of China (China) (CN)
Lightning and Electromagnetic Phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon