Assessment of the calibration capability of KRISS for noble-metal thermocouples

The Korea Research Institute of Standards and Science (KRISS) maintains the national temperature standards and provides high-accuracy calibration services exclusively for noble-metal thermocouples (Types R, S and B). Most industrial users prefer comparison calibration to primary fixed-point calibration because the latter is time-consuming and costly. Comparison calibrations, however, carry larger uncertainties, and values above 1100 °C must be obtained by extrapolation, which further increases the uncertainty. To establish the reliability of this practical approach, a comprehensive assessment of KRISS’s thermocouple calibration capability was undertaken. Three Type R reference thermocouples were prepared, characterized for thermoelectric inhomogeneity, and calibrated at the ITS-90 fixed points (Sn, Zn, Al, Ag, Cu), and Pd melting point realized by the KRISS cell together with selected metal–carbon eutectic points (Fe–C, Co–C and Pd–C) up to 1560 °C. The same thermocouples were then mutually intercompared in a fully automated comparison system up to 1100 °C, after which the deviation functions were extrapolated to 1600 °C. Temperature differences between the extrapolated comparison results and the independent fixed-point calibrations remained within ±0.3 °C across the entire range—substantially smaller than the expanded uncertainties assigned to routine comparison calibrations (0.8 °C from the ice point to 1100 °C and 1.6 °C from 1100 °C to 1600 °C). These results demonstrate that fixed-point-calibrated reference thermocouples can be used for routine comparison calibrations limited to 1100 °C with subsequent extrapolation to 1600 °C, while remaining fully consistent with the primary temperature scale. The combination of primary fixed-point realization, mutual inter-comparison, and validated extrapolation therefore provides a practical and fully traceable foundation for KRISS’s thermocouple calibration services.

Authors

Institutions

Publication Details

Journal
Metrologia
Published
2026-11-18
DOI
https://doi.org/10.1088/1681-7575/aec3aa
Primary Topic
Calibration and Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Assessment of the calibration capability of KRISS for noble-metal thermocouples

Yong-Gyoo Kim, Sunghun Kim, Suyong Kwon, Young Hee Lee
Metrologia
Calibration and Measurement Techniques
article

Assessment of the calibration capability of KRISS for noble-metal thermocouples

Yong-Gyoo Kim, Sunghun Kim, Suyong Kwon, Young Hee Lee
article en

Abstract

The Korea Research Institute of Standards and Science (KRISS) maintains the national temperature standards and provides high-accuracy calibration services exclusively for noble-metal thermocouples (Types R, S and B). Most industrial users prefer comparison calibration to primary fixed-point calibration because the latter is time-consuming and costly. Comparison calibrations, however, carry larger uncertainties, and values above 1100 °C must be obtained by extrapolation, which further increases the uncertainty. To establish the reliability of this practical approach, a comprehensive assessment of KRISS’s thermocouple calibration capability was undertaken. Three Type R reference thermocouples were prepared, characterized for thermoelectric inhomogeneity, and calibrated at the ITS-90 fixed points (Sn, Zn, Al, Ag, Cu), and Pd melting point realized by the KRISS cell together with selected metal–carbon eutectic points (Fe–C, Co–C and Pd–C) up to 1560 °C. The same thermocouples were then mutually intercompared in a fully automated comparison system up to 1100 °C, after which the deviation functions were extrapolated to 1600 °C. Temperature differences between the extrapolated comparison results and the independent fixed-point calibrations remained within ±0.3 °C across the entire range—substantially smaller than the expanded uncertainties assigned to routine comparison calibrations (0.8 °C from the ice point to 1100 °C and 1.6 °C from 1100 °C to 1600 °C). These results demonstrate that fixed-point-calibrated reference thermocouples can be used for routine comparison calibrations limited to 1100 °C with subsequent extrapolation to 1600 °C, while remaining fully consistent with the primary temperature scale. The combination of primary fixed-point realization, mutual inter-comparison, and validated extrapolation therefore provides a practical and fully traceable foundation for KRISS’s thermocouple calibration services.

Metrologia
Korea Research Institute of Standards and Science (KR)
Calibration and Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon