Association Between Mechanical Power and Ventilator-Associated Conditions in Patients Requiring Prolonged Mechanical Ventilation: A Multi-Database Retrospective Cohort Study

Background: While mechanical power (MP) quantifies energy transfer during ventilation, its relationship with ventilator-associated conditions (VAC) remains underexplored. We hypothesized that predicted body weight (PBW)-adjusted mechanical power (MPW) is independently associated with VAC and mortality in patients requiring prolonged ventilation. Methods: This multi-database retrospective cohort study included 14,694 patients requiring prolonged mechanical ventilation (≥14 years; ≥96 h of ventilation) from MIMIC-III and eICU, with verification in an independent local cohort. The primary outcome was 28-day VAC; secondary outcomes were mortality and ventilator-free days. We employed Cox models, Bayesian joint longitudinal-survival analysis, and a competing-risk analysis treating 28-day death as a competing event. Results: VAC occurred in 8.2% (n = 1209) of 14,694 patients. Each 0.1 J·min−1·kg−1 MPW increase independently predicted a higher VAC hazard ratio (HR 1.04, 95% credible interval [CI] 1.02–1.06, p < 0.001) and 28-day mortality (HR 1.03, 95% CI 1.01–1.04, p = 0.01). Bayesian modeling revealed a time-dependent MPW effect, peaking at day 22 (HR 1.12, 95% credible interval (CI) 1.08–1.17). Patients exceeding the receiver operating characteristic (ROC) curve-derived MPW threshold (0.262 J·min−1·kg−1) had a higher VAC hazard (HR 1.36, 95% CI 1.21–1.52, p < 0.001). With death as a competing event for VAC, the association persisted (subdistribution HR 1.25, 1.11–1.41; Gray’s test p < 0.001), whereas cumulative death incidence did not differ by MPW group (p = 0.968). In an independent local cohort (n = 196; 12 VAC events), the core analyses were replicated with directionally consistent results (MPW-threshold adjusted hazard ratio 3.96, 95% CI 1.01–15.54; Bayesian time-varying effect rising from <1 to approximately 6.6 per 0.1 J·min−1·kg−1 by day 30). Conclusions: MPW was independently associated with VAC and mortality. These findings support further study of mechanical-power-guided ventilation strategies and require validation before clinical use.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2026-11-18
DOI
https://doi.org/10.3390/jcm15229051
Primary Topic
Respiratory Support and Mechanisms
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Association Between Mechanical Power and Ventilator-Associated Conditions in Patients Requiring Prolonged Mechanical Ventilation: A Multi-Database Retrospective Cohort Study

Jiang Du, Xinan Dong, Changshe Wang, Dan Zhang et al.
5 links
Journal of Clinical Medicine
Respiratory Support and Mechanisms
article

Association Between Mechanical Power and Ventilator-Associated Conditions in Patients Requiring Prolonged Mechanical Ventilation: A Multi-Database Retrospective Cohort Study

Jiang Du, Xinan Dong, Changshe Wang, Dan Zhang, Hua Sui, Lingyun Zhang, Xiaoyin She, Jie Xie, Xiaohan Cheng, Shuyi Dong
article en

Abstract

Background: While mechanical power (MP) quantifies energy transfer during ventilation, its relationship with ventilator-associated conditions (VAC) remains underexplored. We hypothesized that predicted body weight (PBW)-adjusted mechanical power (MPW) is independently associated with VAC and mortality in patients requiring prolonged ventilation. Methods: This multi-database retrospective cohort study included 14,694 patients requiring prolonged mechanical ventilation (≥14 years; ≥96 h of ventilation) from MIMIC-III and eICU, with verification in an independent local cohort. The primary outcome was 28-day VAC; secondary outcomes were mortality and ventilator-free days. We employed Cox models, Bayesian joint longitudinal-survival analysis, and a competing-risk analysis treating 28-day death as a competing event. Results: VAC occurred in 8.2% (n = 1209) of 14,694 patients. Each 0.1 J·min−1·kg−1 MPW increase independently predicted a higher VAC hazard ratio (HR 1.04, 95% credible interval [CI] 1.02–1.06, p < 0.001) and 28-day mortality (HR 1.03, 95% CI 1.01–1.04, p = 0.01). Bayesian modeling revealed a time-dependent MPW effect, peaking at day 22 (HR 1.12, 95% credible interval (CI) 1.08–1.17). Patients exceeding the receiver operating characteristic (ROC) curve-derived MPW threshold (0.262 J·min−1·kg−1) had a higher VAC hazard (HR 1.36, 95% CI 1.21–1.52, p < 0.001). With death as a competing event for VAC, the association persisted (subdistribution HR 1.25, 1.11–1.41; Gray’s test p < 0.001), whereas cumulative death incidence did not differ by MPW group (p = 0.968). In an independent local cohort (n = 196; 12 VAC events), the core analyses were replicated with directionally consistent results (MPW-threshold adjusted hazard ratio 3.96, 95% CI 1.01–15.54; Bayesian time-varying effect rising from <1 to approximately 6.6 per 0.1 J·min−1·kg−1 by day 30). Conclusions: MPW was independently associated with VAC and mortality. These findings support further study of mechanical-power-guided ventilation strategies and require validation before clinical use.

Journal of Clinical MedicineVol. 15(22)
Shanghai Jiao Tong University (CN), Jiading District Central Hospital (CN), Shanghai First People's Hospital (CN)
Good health and well-being
Respiratory Support and Mechanisms
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon