Comparison of Horizontal and Vertical Tonovet Plus Clinical Measurement Configurations for Intraocular Pressure Assessment in Conscious Cats

Rebound tonometry is widely used for measuring intraocular pressure (IOP) in cats; however, differences in clinical tonometer measurement configuration may contribute to variability in recorded values. This prospective repeated-measures study compared IOP measurements obtained using horizontal and vertical Tonovet Plus clinical measurement configurations in 32 client-owned, systemically and ophthalmologically normal conscious cats. Intraocular pressure was measured in the right eye while the probe was directed toward the center of the cornea and positioned 4-8 mm from the corneal surface. The order of horizontal and vertical configurations was randomized for each cat. Measurements were obtained by one experienced veterinary ophthalmologist and a trained student operator group. In the primary linear mixed-effects analysis accounting for repeated measurements within cats, horizontal configuration was associated with an estimated 2.41-mmHg higher IOP than vertical configuration (β = 2.41 mmHg; 95% CI, 1.39-3.44; p < 0.001). The configuration-associated difference was also observed separately for the experienced instructor (mean difference, 2.81 mmHg; 95% CI, 1.91-3.71; p < 0.001) and across the trained student operator group (2.00 mmHg; 95% CI, 0.81-3.19; p = 0.002). These findings indicate that horizontal and vertical Tonovet Plus clinical measurement configurations may yield different IOP values in conscious cats. As configuration changes may affect instrument handling, restraint, head positioning, and animal responses, the difference cannot be attributed solely to tonometer orientation or mechanics. Consistent configuration is therefore recommended when comparing serial IOP measurements in cats. Further controlled studies are needed to distinguish mechanical, ergonomic, and other examination-related mechanisms.

Authors

Institutions

Publication Details

Journal
Veterinary Ophthalmology
Published
2026-11-18
DOI
https://doi.org/10.1111/vop.70304
Primary Topic
Glaucoma and retinal disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Comparison of Horizontal and Vertical Tonovet Plus Clinical Measurement Configurations for Intraocular Pressure Assessment in Conscious Cats

Batuhan Neyse, Yusuf Sinan SİRİN, Mehmet Nur Çetin, Latif Emrah Yanmaz et al.
1 links
Veterinary Ophthalmology
Glaucoma and retinal disorders
article

Comparison of Horizontal and Vertical Tonovet Plus Clinical Measurement Configurations for Intraocular Pressure Assessment in Conscious Cats

Batuhan Neyse, Yusuf Sinan SİRİN, Mehmet Nur Çetin, Latif Emrah Yanmaz, Dogukan Polat
article en

Abstract

Rebound tonometry is widely used for measuring intraocular pressure (IOP) in cats; however, differences in clinical tonometer measurement configuration may contribute to variability in recorded values. This prospective repeated-measures study compared IOP measurements obtained using horizontal and vertical Tonovet Plus clinical measurement configurations in 32 client-owned, systemically and ophthalmologically normal conscious cats. Intraocular pressure was measured in the right eye while the probe was directed toward the center of the cornea and positioned 4-8 mm from the corneal surface. The order of horizontal and vertical configurations was randomized for each cat. Measurements were obtained by one experienced veterinary ophthalmologist and a trained student operator group. In the primary linear mixed-effects analysis accounting for repeated measurements within cats, horizontal configuration was associated with an estimated 2.41-mmHg higher IOP than vertical configuration (β = 2.41 mmHg; 95% CI, 1.39-3.44; p < 0.001). The configuration-associated difference was also observed separately for the experienced instructor (mean difference, 2.81 mmHg; 95% CI, 1.91-3.71; p < 0.001) and across the trained student operator group (2.00 mmHg; 95% CI, 0.81-3.19; p = 0.002). These findings indicate that horizontal and vertical Tonovet Plus clinical measurement configurations may yield different IOP values in conscious cats. As configuration changes may affect instrument handling, restraint, head positioning, and animal responses, the difference cannot be attributed solely to tonometer orientation or mechanics. Consistent configuration is therefore recommended when comparing serial IOP measurements in cats. Further controlled studies are needed to distinguish mechanical, ergonomic, and other examination-related mechanisms.

Veterinary OphthalmologyVol. 30(1)
Istanbul University-Cerrahpaşa (TR), Burdur Mehmet Akif Ersoy Üniversitesi (TR), Istanbul University (TR)
Good health and well-being
Glaucoma and retinal disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon