Association of passive posterolateral corner rotational compliance with tibial external-rotation excursion during functional movement: a cross-sectional laboratory study

Importance The posterolateral corner (PLC) is the principal passive restraint to tibial external rotation, but whether PLC compliance relates to cutting external-rotation excursion in uninjured knees remains unclear. Objective The aim of this study is to estimate the association between passive PLC rotational compliance and tibial external-rotation excursion during 45-degree cutting. Design, setting, and participants A single-center, cross-sectional laboratory study was conducted on 33 uninjured athletes (January–February 2026) who underwent passive laxity testing, ultrasound with shear-wave elastography, and three-dimensional motion capture. Exposure PLC rotational compliance (deg/Nm): tibial external rotation under a 10-N·m torque, relative to 0 N·m, divided by torque; mean of two supine trials at each of 30°, 60°, and 90°. Main outcomes and measures Primary outcomes included tibial external-rotation excursion during cutting (peak minus initial-contact angle; mean of three trials). Secondary outcomes included other tasks, kinetics, and ultrasound measures, including fibular collateral ligament (FCL) strain (load-induced elongation/pre-load length). Results Among 33 participants (17 [52%] female; mean [SD] age, 21.4 [2.3] years), compliance decreased from 30° to 90° (−0.34 deg/Nm; 95% CI = −0.37 to −0.30), and external-rotation loading increased FCL strain at 30° by 4.0 percentage points (95% CI, 3.8–4.3). Compliance had high within-session reliability (intraclass correlation coefficient = 0.88–0.93). Greater compliance was associated with greater excursion in unadjusted analysis (β = 3.1 deg per deg/Nm; 95% CI = 0.7–5.6; P = 0.014); after prespecified adjustment, the estimate was attenuated, primarily by sex, was not statistically significant (β = 1.9; 95% CI = −0.6 to 4.4; P = 0.130), and was sensitive to two influential participants. The standardized adjusted compliance coefficient was 0.26 (95% CI = −0.08 to 0.59), compatible with null to large associations. Trial-level estimates were similar for cutting (β = 2.3; 95% CI = −0.2 to 4.8; P = 0.069) and, post hoc , for all tasks pooled (β = 2.4; 95% CI = 0.3–4.6). No secondary association across the three prespecified false-discovery-rate families remained significant after controlling the false discovery rate at 5%. Conclusion and relevance The association between passive PLC compliance and cutting excursion was largely shared with sex; after adjustment, it was neither established nor excluded. In uninjured athletes, when sex is considered, supine passive compliance should not be regarded as interchangeable with dynamic excursion or as a substitute for dynamic assessment.

Authors

Institutions

Publication Details

Journal
Frontiers in Bioengineering and Biotechnology
Published
2026-11-18
DOI
https://doi.org/10.3389/fbioe.2026.1967094
Primary Topic
Knee injuries and reconstruction techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Association of passive posterolateral corner rotational compliance with tibial external-rotation excursion during functional movement: a cross-sectional laboratory study

Xiao Xiao, Zichao Xue, Xiao Fan, Hui Shen et al.
1 links
Frontiers in Bioengineering and Biotechnology
Knee injuries and reconstruction techniques
article

Association of passive posterolateral corner rotational compliance with tibial external-rotation excursion during functional movement: a cross-sectional laboratory study

Xiao Xiao, Zichao Xue, Xiao Fan, Hui Shen, Zhenxing Wen, Dapeng Li, Yuan Ding
article en

Abstract

Importance The posterolateral corner (PLC) is the principal passive restraint to tibial external rotation, but whether PLC compliance relates to cutting external-rotation excursion in uninjured knees remains unclear. Objective The aim of this study is to estimate the association between passive PLC rotational compliance and tibial external-rotation excursion during 45-degree cutting. Design, setting, and participants A single-center, cross-sectional laboratory study was conducted on 33 uninjured athletes (January–February 2026) who underwent passive laxity testing, ultrasound with shear-wave elastography, and three-dimensional motion capture. Exposure PLC rotational compliance (deg/Nm): tibial external rotation under a 10-N·m torque, relative to 0 N·m, divided by torque; mean of two supine trials at each of 30°, 60°, and 90°. Main outcomes and measures Primary outcomes included tibial external-rotation excursion during cutting (peak minus initial-contact angle; mean of three trials). Secondary outcomes included other tasks, kinetics, and ultrasound measures, including fibular collateral ligament (FCL) strain (load-induced elongation/pre-load length). Results Among 33 participants (17 [52%] female; mean [SD] age, 21.4 [2.3] years), compliance decreased from 30° to 90° (−0.34 deg/Nm; 95% CI = −0.37 to −0.30), and external-rotation loading increased FCL strain at 30° by 4.0 percentage points (95% CI, 3.8–4.3). Compliance had high within-session reliability (intraclass correlation coefficient = 0.88–0.93). Greater compliance was associated with greater excursion in unadjusted analysis (β = 3.1 deg per deg/Nm; 95% CI = 0.7–5.6; P = 0.014); after prespecified adjustment, the estimate was attenuated, primarily by sex, was not statistically significant (β = 1.9; 95% CI = −0.6 to 4.4; P = 0.130), and was sensitive to two influential participants. The standardized adjusted compliance coefficient was 0.26 (95% CI = −0.08 to 0.59), compatible with null to large associations. Trial-level estimates were similar for cutting (β = 2.3; 95% CI = −0.2 to 4.8; P = 0.069) and, post hoc , for all tasks pooled (β = 2.4; 95% CI = 0.3–4.6). No secondary association across the three prespecified false-discovery-rate families remained significant after controlling the false discovery rate at 5%. Conclusion and relevance The association between passive PLC compliance and cutting excursion was largely shared with sex; after adjustment, it was neither established nor excluded. In uninjured athletes, when sex is considered, supine passive compliance should not be regarded as interchangeable with dynamic excursion or as a substitute for dynamic assessment.

Frontiers in Bioengineering and BiotechnologyVol. 14
Qingdao University (CN), Qingdao Municipal Hospital (CN)
Good health and well-being
Knee injuries and reconstruction techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon