Fixation beat distribution across transseptal transitions during left bundle branch pacing: availability varies among patients

Introduction Fixation beat morphology marks septal lead depth during left bundle branch pacing, and such beats have been observed at distinct transseptal transitions. Whether their distribution across these transitions varies among patients, and whether early occurrence informs later availability, is unknown. Methods We retrospectively studied 396 patients with confirmed left bundle branch capture under continuous pacing and recording; 369 with atrioventricular block (AVB) or sick sinus syndrome (SSS) formed the comparison cohort. Fixation beats were assessed at current of injury rise, V1 terminal R/r wave appearance, and abrupt paced QRS transition. Outcomes were any occurrence, recurrence at ≥2 evaluable transitions, and intensity per positive transition. Results Fixation beats at current of injury rise were associated with later reappearance [adjusted odds ratio [OR] 2.55, 95% confidence interval [CI] 1.59–4.14]. Recurrence was more frequent in AVB than in SSS (44.6% vs. 22.2%; adjusted OR 2.95, 95% CI 1.74–5.16), whereas any occurrence (76.4% vs. 67.3%; adjusted OR 1.54, 95% CI 0.90–2.61) and intensity (adjusted incidence rate ratio 1.14, 95% CI 0.94–1.39) showed no statistically clear differences. The AVB association was stronger for recurrence than any occurrence (ratio of ORs 1.88, 95% CI 1.07–3.31). Conclusion Fixation beat distribution across transitions varied by pacing indication, with the AVB–SSS difference centered on recurrence rather than any occurrence or intensity. Fixation beat availability may reflect patient level differences in addition to procedural factors. The presence of fixation beats at the current of injury rise transition informs expectations for later availability; with continuous pacing and transition based assessment, the absence of fixation beats at a subsequent transition does not necessarily call for further lead manipulation.

Authors

Institutions

Publication Details

Journal
Frontiers in Cardiovascular Medicine
Published
2026-11-18
DOI
https://doi.org/10.3389/fcvm.2026.2008812
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Fixation beat distribution across transseptal transitions during left bundle branch pacing: availability varies among patients

longfu jiang, Jiabo Shen, Hengdong Li, Binbin Luo et al.
5 links
Frontiers in Cardiovascular Medicine
Cardiac pacing and defibrillation studies
article

Fixation beat distribution across transseptal transitions during left bundle branch pacing: availability varies among patients

longfu jiang, Jiabo Shen, Hengdong Li, Binbin Luo, Ding Yuan, Lu Zhang, Hao Wu
article en

Abstract

Introduction Fixation beat morphology marks septal lead depth during left bundle branch pacing, and such beats have been observed at distinct transseptal transitions. Whether their distribution across these transitions varies among patients, and whether early occurrence informs later availability, is unknown. Methods We retrospectively studied 396 patients with confirmed left bundle branch capture under continuous pacing and recording; 369 with atrioventricular block (AVB) or sick sinus syndrome (SSS) formed the comparison cohort. Fixation beats were assessed at current of injury rise, V1 terminal R/r wave appearance, and abrupt paced QRS transition. Outcomes were any occurrence, recurrence at ≥2 evaluable transitions, and intensity per positive transition. Results Fixation beats at current of injury rise were associated with later reappearance [adjusted odds ratio [OR] 2.55, 95% confidence interval [CI] 1.59–4.14]. Recurrence was more frequent in AVB than in SSS (44.6% vs. 22.2%; adjusted OR 2.95, 95% CI 1.74–5.16), whereas any occurrence (76.4% vs. 67.3%; adjusted OR 1.54, 95% CI 0.90–2.61) and intensity (adjusted incidence rate ratio 1.14, 95% CI 0.94–1.39) showed no statistically clear differences. The AVB association was stronger for recurrence than any occurrence (ratio of ORs 1.88, 95% CI 1.07–3.31). Conclusion Fixation beat distribution across transitions varied by pacing indication, with the AVB–SSS difference centered on recurrence rather than any occurrence or intensity. Fixation beat availability may reflect patient level differences in addition to procedural factors. The presence of fixation beats at the current of injury rise transition informs expectations for later availability; with continuous pacing and transition based assessment, the absence of fixation beats at a subsequent transition does not necessarily call for further lead manipulation.

Frontiers in Cardiovascular MedicineVol. 13
Wenzhou Medical University (CN), Ningbo No. 2 Hospital (CN)
Good health and well-being
Cardiac pacing and defibrillation studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon