A real-time explainable machine learning framework for wide-area fault detection and localization using optimally placed synchrophasor measurements

Modern transmission networks face increasing protection challenges due to renewable energy integration, bidirectional power flows, high-impedance faults (HIFs), and potential failures of local protection devices, motivating the development of intelligent wide-area protection schemes. This paper presents a distributed real-time framework for wide-area fault detection and localization using synchrophasor measurements. Optimal Phasor Measurement Unit (PMU) placement is achieved using Binary Integer Linear Programming (BILP) to ensure complete network observability with the minimum number of PMUs. A Virtual PMU implemented in the OPAL-RT HYPERSIM real-time simulator streams synchrophasor measurements via the IEEE C37.118 protocol over User Datagram Protocol (UDP) to a separate computer, where a multilayer Artificial Neural Network (ANN) and a Support Vector Machine (SVM) perform real-time inference for fault detection and faulted-line identification. The framework is evaluated on the IEEE 9-bus system under symmetrical, asymmetrical, and high-impedance fault conditions (up to 90 Ω in testing, 80 Ω in training). The ANN reaches 98.68 % ± 0.10 % test accuracy (mean ± SD, 5 training runs) with zero false positives; the SVM reaches 98.37 % ± 0.06 %. The estimated average inception-to-decision latency is ≈9.4 ms (8.33 ms average PMU frame-waiting time, ∼0.5 ms estimated communication/IEEE C37.118 processing, ∼0.5 ms estimated feature extraction, and 0.083 ms measured Artificial Neural Network (ANN) inference), with a worst-case PMU frame-waiting time of 16.67 ms at 60 frames/s well within the 50–150 ms fault duration range in the dataset. The trained models are not inherently topology-adaptive; however, topology-aware retraining on additional samples recovers both models to at least 98.7 % accuracy across all evaluated topology-change scenarios. SHapley Additive exPlanations (SHAP) analysis identifies current magnitude features at THE three PMU buses as the dominant fault-discriminating features, consistent with (though not an independent statistical proof of) the BILP placement strategy. These results demonstrate that combining optimized PMU placement, real-time synchrophasor communication, and explainable machine learning enables fast, accurate, and transparent wide-area protection suitable for next-generation transmission systems.

Authors

Institutions

Publication Details

Journal
at - Automatisierungstechnik
Published
2026-11-18
DOI
https://doi.org/10.1515/auto-2026-0141
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A real-time explainable machine learning framework for wide-area fault detection and localization using optimally placed synchrophasor measurements

Martin Wolter, Artem Kashtanov, Adegbenga Adeyemi, Elijah Osunkentan
at - Automatisierungstechnik
Power Systems Fault Detection
article

A real-time explainable machine learning framework for wide-area fault detection and localization using optimally placed synchrophasor measurements

Martin Wolter, Artem Kashtanov, Adegbenga Adeyemi, Elijah Osunkentan
article en

Abstract

Modern transmission networks face increasing protection challenges due to renewable energy integration, bidirectional power flows, high-impedance faults (HIFs), and potential failures of local protection devices, motivating the development of intelligent wide-area protection schemes. This paper presents a distributed real-time framework for wide-area fault detection and localization using synchrophasor measurements. Optimal Phasor Measurement Unit (PMU) placement is achieved using Binary Integer Linear Programming (BILP) to ensure complete network observability with the minimum number of PMUs. A Virtual PMU implemented in the OPAL-RT HYPERSIM real-time simulator streams synchrophasor measurements via the IEEE C37.118 protocol over User Datagram Protocol (UDP) to a separate computer, where a multilayer Artificial Neural Network (ANN) and a Support Vector Machine (SVM) perform real-time inference for fault detection and faulted-line identification. The framework is evaluated on the IEEE 9-bus system under symmetrical, asymmetrical, and high-impedance fault conditions (up to 90 Ω in testing, 80 Ω in training). The ANN reaches 98.68 % ± 0.10 % test accuracy (mean ± SD, 5 training runs) with zero false positives; the SVM reaches 98.37 % ± 0.06 %. The estimated average inception-to-decision latency is ≈9.4 ms (8.33 ms average PMU frame-waiting time, ∼0.5 ms estimated communication/IEEE C37.118 processing, ∼0.5 ms estimated feature extraction, and 0.083 ms measured Artificial Neural Network (ANN) inference), with a worst-case PMU frame-waiting time of 16.67 ms at 60 frames/s well within the 50–150 ms fault duration range in the dataset. The trained models are not inherently topology-adaptive; however, topology-aware retraining on additional samples recovers both models to at least 98.7 % accuracy across all evaluated topology-change scenarios. SHapley Additive exPlanations (SHAP) analysis identifies current magnitude features at THE three PMU buses as the dominant fault-discriminating features, consistent with (though not an independent statistical proof of) the BILP placement strategy. These results demonstrate that combining optimized PMU placement, real-time synchrophasor communication, and explainable machine learning enables fast, accurate, and transparent wide-area protection suitable for next-generation transmission systems.

at - AutomatisierungstechnikVol. 74(11)
Universidade Federal do ABC (BR), Otto-von-Guericke-Universität Magdeburg (DE)
Industry, innovation and infrastructure
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon