Lorentz Violation Bounds from Neutron Interferometry: Phase Limits at the Institut Laue-Langevin

A neutron interferometer splits a neutron beam between two paths in a silicon crystal and reads the phase difference, and the absence of any anomalous phase limits Lorentz violation for neutrons. The phase shift is 0.001 radians, the leading coefficient comes out at 1 × 10^-8, and the ratio to the published limit is 1. Five coefficients are stated, each the phase divided by its sensitivity, with the second coefficient at 1.111 × 10^-8 and the fifth at 2.5 × 10^-8. The free fall time is 0.01 seconds and the arm separation is 0.001 metres. The result is computed from the published interferometer limit and the stated sensitivities, not measured here, and it is the neutron-sector anchor of the laboratory bounds.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-18
DOI
https://doi.org/10.5281/zenodo.24332371
Primary Topic
Noncommutative and Quantum Gravity Theories
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Lorentz Violation Bounds from Neutron Interferometry: Phase Limits at the Institut Laue-Langevin

William Alexander Aldred
2 links
Zenodo (CERN European Organization for Nuclear Research)
Noncommutative and Quantum Gravity Theories
article

Lorentz Violation Bounds from Neutron Interferometry: Phase Limits at the Institut Laue-Langevin

William Alexander Aldred
article en

Abstract

A neutron interferometer splits a neutron beam between two paths in a silicon crystal and reads the phase difference, and the absence of any anomalous phase limits Lorentz violation for neutrons. The phase shift is 0.001 radians, the leading coefficient comes out at 1 × 10^-8, and the ratio to the published limit is 1. Five coefficients are stated, each the phase divided by its sensitivity, with the second coefficient at 1.111 × 10^-8 and the fifth at 2.5 × 10^-8. The free fall time is 0.01 seconds and the arm separation is 0.001 metres. The result is computed from the published interferometer limit and the stated sensitivities, not measured here, and it is the neutron-sector anchor of the laboratory bounds.

Zenodo (CERN European Organization for Nuclear Research)
Noncommutative and Quantum Gravity Theories
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon