Thermodynamic and Exergetic Analysis of a Two‐Stage Ammonia–Water Absorption Cycle for Simultaneous Power and Refrigeration Generation

ABSTRACT This paper presents a comprehensive thermodynamic and exergetic analysis of a novel two‐stage ammonia–water absorption power and refrigeration cycle designed to simultaneously produce mechanical power and cooling. The proposed configuration employs two generators operating at different temperature levels, enabling internal thermal energy recovery and more effective utilization of the supplied heat. Mass and energy balances were rigorously developed for all key components, including high‐ and low‐temperature generators, turbines, heat exchangers, a condenser, an evaporator, and an absorber. Thermodynamic properties of the working fluid were calculated using the Engineering Equation Solver software. The results demonstrate that the proposed cycle achieves a net power output of 65.3 kW with a notable thermal efficiency of 93%. Simultaneously, it delivers a significant cooling capacity of 549.4 kW, corresponding to a refrigeration coefficient of performance (COP) of 0.83. The exergy efficiency of the cycle is calculated at 42.78%. A comparative analysis shows that the proposed two‐stage configuration achieves a comparable COP and higher refrigeration capacity than the double‐effect reference cycle, with COP increasing from 0.80 to 0.83 and refrigeration capacity increasing from 520 to 549.4 kW. The parametric analysis showed that ammonia concentration and generator temperature strongly affect net power output, while evaporator and absorber temperatures significantly influence the refrigeration performance and COP of the proposed cycle. The proposed configuration provides a thermodynamic framework for the simultaneous utilization of thermal energy for power and refrigeration and represents a viable solution for integrated cooling and power applications, particularly where both outputs are required in industrial and utility‐scale applications.

Authors

Institutions

Publication Details

Journal
Energy Science & Engineering
Published
2026-11-17
DOI
https://doi.org/10.1002/ese3.70696
Primary Topic
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Thermodynamic and Exergetic Analysis of a Two‐Stage Ammonia–Water Absorption Cycle for Simultaneous Power and Refrigeration Generation

Elahe Soleymani, Hadi Ghaebi, Mohammad Ranjbar Hassani
Energy Science & Engineering
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
article

Thermodynamic and Exergetic Analysis of a Two‐Stage Ammonia–Water Absorption Cycle for Simultaneous Power and Refrigeration Generation

Elahe Soleymani, Hadi Ghaebi, Mohammad Ranjbar Hassani
article en

Abstract

ABSTRACT This paper presents a comprehensive thermodynamic and exergetic analysis of a novel two‐stage ammonia–water absorption power and refrigeration cycle designed to simultaneously produce mechanical power and cooling. The proposed configuration employs two generators operating at different temperature levels, enabling internal thermal energy recovery and more effective utilization of the supplied heat. Mass and energy balances were rigorously developed for all key components, including high‐ and low‐temperature generators, turbines, heat exchangers, a condenser, an evaporator, and an absorber. Thermodynamic properties of the working fluid were calculated using the Engineering Equation Solver software. The results demonstrate that the proposed cycle achieves a net power output of 65.3 kW with a notable thermal efficiency of 93%. Simultaneously, it delivers a significant cooling capacity of 549.4 kW, corresponding to a refrigeration coefficient of performance (COP) of 0.83. The exergy efficiency of the cycle is calculated at 42.78%. A comparative analysis shows that the proposed two‐stage configuration achieves a comparable COP and higher refrigeration capacity than the double‐effect reference cycle, with COP increasing from 0.80 to 0.83 and refrigeration capacity increasing from 520 to 549.4 kW. The parametric analysis showed that ammonia concentration and generator temperature strongly affect net power output, while evaporator and absorber temperatures significantly influence the refrigeration performance and COP of the proposed cycle. The proposed configuration provides a thermodynamic framework for the simultaneous utilization of thermal energy for power and refrigeration and represents a viable solution for integrated cooling and power applications, particularly where both outputs are required in industrial and utility‐scale applications.

Energy Science & Engineering
University of Mohaghegh Ardabili (IR)
Thermodynamic and Exergetic Analyses of Power and Cooling Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon