The influence of wind effects on the amount of heat loss of enclosing structures in the Far North

The article examines the problem of the impact of prolonged wind exposure on the magnitude of heat loss through building envelope structures in the Far North. Based on an analytical review of regulatory documents, domestic and foreign scientific works, as well as archival data from the Anadyr weather station for the period from 2020 to 2025, an analysis of heat loss was carried out, taking into account the impact of wind exposure at the нормируемых values of outdoor air temperatures. Empirical relationships proposed by Frank and Jürges were used to determine the heat transfer coefficient for the outer surface of building envelope structures. The study showed that the standard value of the heat transfer coefficient, adopted in accordance with SP 50.13330.2024 “Thermal Protection of Buildings,” requires clarification for certain Arctic regions with high wind activity. Exceeding the standard value of the heat transfer coefficient αn is observed at wind speeds of 5–6 m/s for a rough surface and 7–8 m/s for a smooth surface. At speeds exceeding 15–20 m/s, the coefficient reaches a value of 37–70 W/(m²·°C), i.e., it exceeds the standard value by 1.6–3 times. Recommendations are proposed for adjusting thermal engineering calculations and improving the energy efficiency of buildings.

Authors

Institutions

Publication Details

Journal
Building and reconstruction
Published
2026-11-17
DOI
https://doi.org/10.33979/2073-7416-2026-127-5-3
Primary Topic
Building energy efficiency and sustainability
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

The influence of wind effects on the amount of heat loss of enclosing structures in the Far North

Вера Агафонова, Oleg Vasil'evich Kabantsev
Building and reconstruction
Building energy efficiency and sustainability
article

The influence of wind effects on the amount of heat loss of enclosing structures in the Far North

Вера Агафонова, Oleg Vasil'evich Kabantsev
article en

Abstract

The article examines the problem of the impact of prolonged wind exposure on the magnitude of heat loss through building envelope structures in the Far North. Based on an analytical review of regulatory documents, domestic and foreign scientific works, as well as archival data from the Anadyr weather station for the period from 2020 to 2025, an analysis of heat loss was carried out, taking into account the impact of wind exposure at the нормируемых values of outdoor air temperatures. Empirical relationships proposed by Frank and Jürges were used to determine the heat transfer coefficient for the outer surface of building envelope structures. The study showed that the standard value of the heat transfer coefficient, adopted in accordance with SP 50.13330.2024 “Thermal Protection of Buildings,” requires clarification for certain Arctic regions with high wind activity. Exceeding the standard value of the heat transfer coefficient αn is observed at wind speeds of 5–6 m/s for a rough surface and 7–8 m/s for a smooth surface. At speeds exceeding 15–20 m/s, the coefficient reaches a value of 37–70 W/(m²·°C), i.e., it exceeds the standard value by 1.6–3 times. Recommendations are proposed for adjusting thermal engineering calculations and improving the energy efficiency of buildings.

Building and reconstruction(5)
Moscow State University of Civil Engineering (RU)
Building energy efficiency and sustainability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon