Comparative Ergonomic Assessment of Microscopic, Endoscopic, and RobOtol®-Assisted Ear Surgery: A Prospective Pilot Study

Background: Otologic surgery imposes prolonged static postures and fine-motor demands on the surgeon, yet the ergonomic effect of robotic endoscope holding is unknown. We compared surgeon-perceived workload, fatigue and workflow during microscopic, conventional endoscopic and RobOtol®-assisted endoscopic ear surgery. Methods: In this prospective single-center pilot study, one surgeon performed 29 procedures: RobOtol® (n = 9), conventional endoscopy (n = 10) and microscopy (n = 10). After each procedure, the surgeon rated five NASA Task Load Index (NASA-TLX)-derived workload domains (0–10; unweighted mean), comfort, neck, eye and hand fatigue, instrument stability and movement precision. Setup time, operative time and repositionings were recorded. Kruskal–Wallis and Holm-adjusted Mann–Whitney U tests were used, with false discovery rate control across secondary outcomes. Rapid Upper Limb Assessment (RULA) scores from intraoperative photographs were analyzed descriptively. Results: Modified NASA-TLX scores were 3.58 ± 1.50 (RobOtol®), 3.78 ± 1.54 (endoscopy) and 5.52 ± 1.54 (microscopy) (p = 0.026, ε2 = 0.26); no pairwise difference remained significant after Holm adjustment. Eye fatigue was higher with microscopy than with either endoscopic approach (adjusted p ≤ 0.016). Compared with conventional endoscopy, RobOtol® yielded higher surgeon-rated instrument stability (mean difference 2.72, 95% CI 1.79–3.65; adjusted p < 0.001) and movement precision (1.04, 95% CI 0.41–1.67; adjusted p = 0.019) without higher workload. Operative time was longest with microscopy (130.7 vs 76.8 and 77.3 min; p = 0.004). Mean RULA scores were 3.38–3.77 (action level 2) in all groups. Conclusions: Endoscopic approaches were associated with lower perceived workload and eye fatigue than microscopy, and robotic endoscope holding was associated with higher perceived stability and precision without added workload. As case mix differed between groups and outcomes were self-rated, these hypothesis-generating findings require confirmation in larger multi-surgeon studies with objective performance and posture measurement.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2026-11-17
DOI
https://doi.org/10.3390/jcm15228998
Primary Topic
Ergonomics and Musculoskeletal Disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Comparative Ergonomic Assessment of Microscopic, Endoscopic, and RobOtol®-Assisted Ear Surgery: A Prospective Pilot Study

Marta Aleksandra Kwiatkowska, Dominika Dobrowolska, Łukasz Skrzypiec, Dariusz Jurkiewicz
Journal of Clinical Medicine
Ergonomics and Musculoskeletal Disorders
article

Comparative Ergonomic Assessment of Microscopic, Endoscopic, and RobOtol®-Assisted Ear Surgery: A Prospective Pilot Study

Marta Aleksandra Kwiatkowska, Dominika Dobrowolska, Łukasz Skrzypiec, Dariusz Jurkiewicz
article en

Abstract

Background: Otologic surgery imposes prolonged static postures and fine-motor demands on the surgeon, yet the ergonomic effect of robotic endoscope holding is unknown. We compared surgeon-perceived workload, fatigue and workflow during microscopic, conventional endoscopic and RobOtol®-assisted endoscopic ear surgery. Methods: In this prospective single-center pilot study, one surgeon performed 29 procedures: RobOtol® (n = 9), conventional endoscopy (n = 10) and microscopy (n = 10). After each procedure, the surgeon rated five NASA Task Load Index (NASA-TLX)-derived workload domains (0–10; unweighted mean), comfort, neck, eye and hand fatigue, instrument stability and movement precision. Setup time, operative time and repositionings were recorded. Kruskal–Wallis and Holm-adjusted Mann–Whitney U tests were used, with false discovery rate control across secondary outcomes. Rapid Upper Limb Assessment (RULA) scores from intraoperative photographs were analyzed descriptively. Results: Modified NASA-TLX scores were 3.58 ± 1.50 (RobOtol®), 3.78 ± 1.54 (endoscopy) and 5.52 ± 1.54 (microscopy) (p = 0.026, ε2 = 0.26); no pairwise difference remained significant after Holm adjustment. Eye fatigue was higher with microscopy than with either endoscopic approach (adjusted p ≤ 0.016). Compared with conventional endoscopy, RobOtol® yielded higher surgeon-rated instrument stability (mean difference 2.72, 95% CI 1.79–3.65; adjusted p < 0.001) and movement precision (1.04, 95% CI 0.41–1.67; adjusted p = 0.019) without higher workload. Operative time was longest with microscopy (130.7 vs 76.8 and 77.3 min; p = 0.004). Mean RULA scores were 3.38–3.77 (action level 2) in all groups. Conclusions: Endoscopic approaches were associated with lower perceived workload and eye fatigue than microscopy, and robotic endoscope holding was associated with higher perceived stability and precision without added workload. As case mix differed between groups and outcomes were self-rated, these hypothesis-generating findings require confirmation in larger multi-surgeon studies with objective performance and posture measurement.

Journal of Clinical MedicineVol. 15(22)
Wojskowy Instytut Medyczny (PL)
Ergonomics and Musculoskeletal Disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon