Pre-Treatment condition and preservative treatment quality of Eucalypt electricity distribution poles in Uganda

The durability of wooden poles is important for reliable electricity distribution. In Uganda, premature failure of treated poles has caused substantial replacement costs, yet the condition of poles presented for treatment and the consistency of preservative treatment achieved by treatment plants have not been sufficiently characterized as potential quality-control concerns. This study assessed moisture content, sapwood depth and drying defects in seasoned Eucalyptus poles before preservation, and preservative penetration and retention after treatment. Two separate and independent sets of poles were assessed. The first comprised 338 untreated, air-seasoned poles awaiting preservative treatment, while the second comprised 338 treated poles, consisting of 278 CCA-treated and 60 creosote-treated poles. Thus, a total of 676 poles were assessed. The poles, obtained from six treatment companies in Uganda, were 9 m, 10 m, 12 m and 14 m in length. Among the untreated poles, mean moisture content was 28,5% at the theoretical ground line (TGL) and 30 % at the midpoint, while mean sapwood depth was 23,75 mm. Sapwood depth was moderately positively correlated with surface-check depth. Among the treated poles, mean CCA penetration was 23 mm at TGL and 21 mm at midpoint, while mean CCA retention was 21,8 kg/m³ and 18,3 kg/m³, respectively. For creosote-treated poles, mean penetration was 27 mm at TGL and 21 mm at midpoint, while mean retention was 254,7 kg/m³ and 173,3 kg/m³, respectively. The results demonstrate variability in pole conditioning, drying defects and preservative-treatment quality among the sampled plants. These conditions may be relevant to subsequent durability, but the study did not follow the sampled poles in service and therefore does not establish them as direct causes of premature failure. The findings support stronger quality control of pole conditioning, drying defects, and preservative penetration and retention before poles enter service.

Authors

Institutions

Publication Details

Journal
Maderas Ciencia y tecnología
Published
2026-11-18
DOI
https://doi.org/10.22320/s0718221x/2026.33
Primary Topic
Wood Treatment and Properties
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Pre-Treatment condition and preservative treatment quality of Eucalypt electricity distribution poles in Uganda

Paul Mugabi, John Ngobi, Peter Kakeeto, Brenda Mujawimana et al.
2 links
Maderas Ciencia y tecnología
Wood Treatment and Properties
article

Pre-Treatment condition and preservative treatment quality of Eucalypt electricity distribution poles in Uganda

Paul Mugabi, John Ngobi, Peter Kakeeto, Brenda Mujawimana, Peter Kityo, Raymond Ainomugisha, Isaac Kinhonhi, Emmanuel Otuko
article en

Abstract

The durability of wooden poles is important for reliable electricity distribution. In Uganda, premature failure of treated poles has caused substantial replacement costs, yet the condition of poles presented for treatment and the consistency of preservative treatment achieved by treatment plants have not been sufficiently characterized as potential quality-control concerns. This study assessed moisture content, sapwood depth and drying defects in seasoned Eucalyptus poles before preservation, and preservative penetration and retention after treatment. Two separate and independent sets of poles were assessed. The first comprised 338 untreated, air-seasoned poles awaiting preservative treatment, while the second comprised 338 treated poles, consisting of 278 CCA-treated and 60 creosote-treated poles. Thus, a total of 676 poles were assessed. The poles, obtained from six treatment companies in Uganda, were 9 m, 10 m, 12 m and 14 m in length. Among the untreated poles, mean moisture content was 28,5% at the theoretical ground line (TGL) and 30 % at the midpoint, while mean sapwood depth was 23,75 mm. Sapwood depth was moderately positively correlated with surface-check depth. Among the treated poles, mean CCA penetration was 23 mm at TGL and 21 mm at midpoint, while mean CCA retention was 21,8 kg/m³ and 18,3 kg/m³, respectively. For creosote-treated poles, mean penetration was 27 mm at TGL and 21 mm at midpoint, while mean retention was 254,7 kg/m³ and 173,3 kg/m³, respectively. The results demonstrate variability in pole conditioning, drying defects and preservative-treatment quality among the sampled plants. These conditions may be relevant to subsequent durability, but the study did not follow the sampled poles in service and therefore does not establish them as direct causes of premature failure. The findings support stronger quality control of pole conditioning, drying defects, and preservative penetration and retention before poles enter service.

Maderas Ciencia y tecnologíaVol. 28
Makerere University (UG)
Wood Treatment and Properties
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon