Rapid fabrication of customizable laser-induced graphene microelectrode arrays

Laser-induced graphene (LIG) electrodes fabricated by CO2 laser scribing have been widely utilized in bioelectronic and sensing applications due to their compatibility with flexible substrates and scalable, cleanroom-free production. The digitally programmable nature of this process enables rapid and customizable electrode patterning. However, the relatively large spot size of the CO2 laser limits fabrication resolution and prevents device miniaturization. Here, we report a novel dual-laser approach for the direct writing of high-resolution, multiplexed, and integrated LIG microelectrode arrays with tunable structural and electrochemical properties. LIG electrodes were fabricated by CO2 laser scribing of flexible polyimide (PI) films. Optimization of the laser power and scribing speed generated LIG electrode tracks with a low sheet resistance (19.2 ± 0.30 Ω sq−1). Raman spectroscopy and scanning electron microscopy confirmed the formation of a three-dimensional, porous graphene-like structure. Device miniaturization was achieved through femtosecond laser micromachining of the PI adhesive insulation layer, producing microelectrode openings with diameters of 20–60 μm. Cyclic voltammetry, differential pulse voltammetry, and electrochemical impedance spectroscopy (EIS) demonstrated a size-dependent enhancement in electrochemical performance. The 30 μm LIG microelectrodes exhibited low electrode-to-electrode and device-to-device variability in 1 kHz impedance (coefficients of variation = 3.13–6.17% and 2.52%, respectively), while maintaining their mechanical integrity, electrical conductivity, and electrochemical performance even after 100 bending cycles at 150° (5.31% ± 2.64% increase in 1 kHz impedance). The rapid, mask-free fabrication of customizable LIG microelectrode arrays highlights the potential of this CO2/fs-laser processing strategy for developing portable, wearable, and disposable electrochemical devices.

Authors

Institutions

Publication Details

Journal
APL Electronic Devices
Published
2026-11-19
DOI
https://doi.org/10.1063/5.0354946
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Rapid fabrication of customizable laser-induced graphene microelectrode arrays

Jadranka Travaš‐Sejdić, Courtney Wilson, Claude Aguergaray, Jeffrey Low
6 links
APL Electronic Devices
Electrochemical sensors and biosensors
article

Rapid fabrication of customizable laser-induced graphene microelectrode arrays

Jadranka Travaš‐Sejdić, Courtney Wilson, Claude Aguergaray, Jeffrey Low
article en

Abstract

Laser-induced graphene (LIG) electrodes fabricated by CO2 laser scribing have been widely utilized in bioelectronic and sensing applications due to their compatibility with flexible substrates and scalable, cleanroom-free production. The digitally programmable nature of this process enables rapid and customizable electrode patterning. However, the relatively large spot size of the CO2 laser limits fabrication resolution and prevents device miniaturization. Here, we report a novel dual-laser approach for the direct writing of high-resolution, multiplexed, and integrated LIG microelectrode arrays with tunable structural and electrochemical properties. LIG electrodes were fabricated by CO2 laser scribing of flexible polyimide (PI) films. Optimization of the laser power and scribing speed generated LIG electrode tracks with a low sheet resistance (19.2 ± 0.30 Ω sq−1). Raman spectroscopy and scanning electron microscopy confirmed the formation of a three-dimensional, porous graphene-like structure. Device miniaturization was achieved through femtosecond laser micromachining of the PI adhesive insulation layer, producing microelectrode openings with diameters of 20–60 μm. Cyclic voltammetry, differential pulse voltammetry, and electrochemical impedance spectroscopy (EIS) demonstrated a size-dependent enhancement in electrochemical performance. The 30 μm LIG microelectrodes exhibited low electrode-to-electrode and device-to-device variability in 1 kHz impedance (coefficients of variation = 3.13–6.17% and 2.52%, respectively), while maintaining their mechanical integrity, electrical conductivity, and electrochemical performance even after 100 bending cycles at 150° (5.31% ± 2.64% increase in 1 kHz impedance). The rapid, mask-free fabrication of customizable LIG microelectrode arrays highlights the potential of this CO2/fs-laser processing strategy for developing portable, wearable, and disposable electrochemical devices.

APL Electronic DevicesVol. 2(4)
University of Auckland (NZ), Auckland University of Technology (NZ), The Dodd-Walls Centre for Photonic and Quantum Technologies (NZ), University of Otago (NZ), MacDiarmid Institute for Advanced Materials and Nanotechnology (NZ)
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon