Higher proton conductivity, lower current density: how inlet water vapour shapes the thermal window of a PEM fuel cell

Proton exchange membrane fuel cells (PEMFCs) are conventionally operated at 60–80 °C on kinetic and conductivity grounds. Increasing temperature can improve proton transport, while at fixed inlet relative humidity and total pressure it also increases the inlet water-vapour fraction and reduces reactant partial pressures. A validated three-dimensional two-phase model of a 20 cm 2 parallel-channel PEMFC at 150 kPa quantified this competition over 20–90 °C and 20–100% relative humidity (RH). Peak power density reached 0.997 W cm −2 at 40 °C, with 30–50 °C values within 1%, a broad plateau not a sharp optimum, falling 14.3% by 80 °C. Under saturation, heating from 40 to 80 °C raised proton conductivity 62% (6.34 to 10.30 S m −1 ) yet reduced current density 21% (2.16 to 1.71 A cm −2 ), as vapour rose from 4.9% to 31.6% of the gas. At a constant inlet dew point referenced to 40 °C and 50% RH, the peak power density still fell by 26.5% between 40 and 80 °C, showing that increasing inlet vapour dilution is not necessary for the thermal penalty. At 40 °C, peak power density varied by only 0.13% across 20–100% RH. PEMFC thermal setpoints reflect the coupled effects of proton transport, membrane hydration, reactant availability and water management, not temperature alone.

Authors

Institutions

Publication Details

Journal
Journal of Power Sources
Published
2026-11-18
DOI
https://doi.org/10.1016/j.jpowsour.2026.241998
Primary Topic
Fuel Cells and Related Materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Higher proton conductivity, lower current density: how inlet water vapour shapes the thermal window of a PEM fuel cell

Siaka Dembele, Ahmed M. Daabo, Homan Hadavinia, Tawfik Badawy et al.
3 links
Journal of Power Sources
Fuel Cells and Related Materials
article

Higher proton conductivity, lower current density: how inlet water vapour shapes the thermal window of a PEM fuel cell

Siaka Dembele, Ahmed M. Daabo, Homan Hadavinia, Tawfik Badawy, Iremise S. Iremise, Ali Mubarak Al-Qahtani
article en

Abstract

Proton exchange membrane fuel cells (PEMFCs) are conventionally operated at 60–80 °C on kinetic and conductivity grounds. Increasing temperature can improve proton transport, while at fixed inlet relative humidity and total pressure it also increases the inlet water-vapour fraction and reduces reactant partial pressures. A validated three-dimensional two-phase model of a 20 cm 2 parallel-channel PEMFC at 150 kPa quantified this competition over 20–90 °C and 20–100% relative humidity (RH). Peak power density reached 0.997 W cm −2 at 40 °C, with 30–50 °C values within 1%, a broad plateau not a sharp optimum, falling 14.3% by 80 °C. Under saturation, heating from 40 to 80 °C raised proton conductivity 62% (6.34 to 10.30 S m −1 ) yet reduced current density 21% (2.16 to 1.71 A cm −2 ), as vapour rose from 4.9% to 31.6% of the gas. At a constant inlet dew point referenced to 40 °C and 50% RH, the peak power density still fell by 26.5% between 40 and 80 °C, showing that increasing inlet vapour dilution is not necessary for the thermal penalty. At 40 °C, peak power density varied by only 0.13% across 20–100% RH. PEMFC thermal setpoints reflect the coupled effects of proton transport, membrane hydration, reactant availability and water management, not temperature alone.

Journal of Power SourcesVol. 700
University of Mosul (IQ), Cairo University (EG), Kingston University London (GB), Jubail Industrial College (SA)
Affordable and clean energy
Fuel Cells and Related Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon