PARTIAL LEAST SQUARE-ASSISTED FTIR SPECTROSCOPY FOR ROUTINE DETECTION AND QUANTIFICATION OF DRUG SUBSTANCE IN JAMU: THIAMIN HCl AS A MODEL

The unauthorized addition of medicinal chemicals, such as thiamin HCl, to jamu pegal linu (muscle aches) by unscrupulous manufacturers poses significant health risks, as uncontrolled doses may lead to adverse side effects. This study aimed to develop a rapid analytical method for the identification and quantification of thiamin HCl in jamu pegal linu using Fourier-transform infrared (FTIR) spectroscopy coupled with partial least squares (PLS) regression. Qualitative analysis was initially performed using thin layer chromatography-densitometry to confirm the absence of thiamin HCl in the commercial samples, thereby ensuring the reliability of subsequent spiking experiments. For quantitative analysis, FTIR spectral data were processed using PLS multivariate calibration with XLSTAT software. The TLC results confirmed that none of the tested samples contained thiamin HCl. The PLS calibration model, developed using selected wavenumbers (3700, 3500, 3200, 3000, 1658, 1650, 1610, 1600, 1500, 1400, 1300, 1200, 1100, 1000, 900, 800, 700, 600, 500, and 400 cm?¹), demonstrated excellent predictive performance with a PRESS value of 0.000028751, RMSEC of 0.000446452, RMSECV of 0.00239794, and an R² of 0.9922. These validation parameters indicate a strong correlation between the actual and predicted concentrations, confirming the method's accuracy and precision. The findings demonstrate that FTIR spectroscopy combined with PLS multivariate calibration is a reliable, rapid, and non-destructive alternative for the routine analysis of thiamin HCl in herbal medicine products. Keywords: Jamu pegal linu, Thiamin HCl, FTIR spectroscopy, partial least square

Authors

Institutions

Publication Details

Journal
Medical Sains Jurnal Ilmiah Kefarmasian
Published
2026-11-18
DOI
https://doi.org/10.37874/ms.v11i4.1932
Primary Topic
Spectroscopy and Chemometric Analyses
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

PARTIAL LEAST SQUARE-ASSISTED FTIR SPECTROSCOPY FOR ROUTINE DETECTION AND QUANTIFICATION OF DRUG SUBSTANCE IN JAMU: THIAMIN HCl AS A MODEL

Fajar Aji Lumakso, Ardi Nugroho, Uzulul Hikmah, Siti Murtafi’ah
1 links
Medical Sains Jurnal Ilmiah Kefarmasian
Spectroscopy and Chemometric Analyses
article

PARTIAL LEAST SQUARE-ASSISTED FTIR SPECTROSCOPY FOR ROUTINE DETECTION AND QUANTIFICATION OF DRUG SUBSTANCE IN JAMU: THIAMIN HCl AS A MODEL

Fajar Aji Lumakso, Ardi Nugroho, Uzulul Hikmah, Siti Murtafi’ah
article en

Abstract

The unauthorized addition of medicinal chemicals, such as thiamin HCl, to jamu pegal linu (muscle aches) by unscrupulous manufacturers poses significant health risks, as uncontrolled doses may lead to adverse side effects. This study aimed to develop a rapid analytical method for the identification and quantification of thiamin HCl in jamu pegal linu using Fourier-transform infrared (FTIR) spectroscopy coupled with partial least squares (PLS) regression. Qualitative analysis was initially performed using thin layer chromatography-densitometry to confirm the absence of thiamin HCl in the commercial samples, thereby ensuring the reliability of subsequent spiking experiments. For quantitative analysis, FTIR spectral data were processed using PLS multivariate calibration with XLSTAT software. The TLC results confirmed that none of the tested samples contained thiamin HCl. The PLS calibration model, developed using selected wavenumbers (3700, 3500, 3200, 3000, 1658, 1650, 1610, 1600, 1500, 1400, 1300, 1200, 1100, 1000, 900, 800, 700, 600, 500, and 400 cm?¹), demonstrated excellent predictive performance with a PRESS value of 0.000028751, RMSEC of 0.000446452, RMSECV of 0.00239794, and an R² of 0.9922. These validation parameters indicate a strong correlation between the actual and predicted concentrations, confirming the method's accuracy and precision. The findings demonstrate that FTIR spectroscopy combined with PLS multivariate calibration is a reliable, rapid, and non-destructive alternative for the routine analysis of thiamin HCl in herbal medicine products. Keywords: Jamu pegal linu, Thiamin HCl, FTIR spectroscopy, partial least square

Medical Sains Jurnal Ilmiah KefarmasianVol. 11(4)
Islamic University of Indonesia (ID)
Universitas Islam Indonesia
Good health and well-being
Spectroscopy and Chemometric Analyses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon