Pulmonary Vessel Control During Minimally Invasive Anatomical Lung Resection: A Retrospective Intercentre Comparison of Selective Polymer Clip Use and Stapler-Only Cohorts

Background/Objectives: Comparative evidence for pulmonary vessel control with polymer clips and staplers is limited. We compared selective Click’aV/Click’aV Plus clip use, often combined with vascular stapling, with stapler-only vessel control. Methods: This retrospective intercentre study included adults undergoing minimally invasive lobectomy or segmentectomy at four Polish centres. Two centres contributed each cohort, with no within-centre comparison in the analysed dataset. The prespecified non-inferiority margins were 100 mL for recorded blood loss and 30 min for operative time, tested hierarchically. Qualitative blood-loss records were recoded to their upper thresholds. Results: The analysis included 202 patients: 99 with selective clip use (CLIC) and 103 with stapler-only control (COMP). Threshold entries comprised 64.5% of available CLIC and 51.5% of COMP blood-loss records. The blood-loss criterion was met under upper-threshold recoding (permutation estimate, 36.8 mL; nominal one-sided 95% upper confidence bound, 72.1 mL; p = 0.0016). Operative-time non-inferiority was not demonstrated (difference, 19.3 min; upper bound, 33.9 min; p = 0.1101). Post hoc propensity-score matching yielded 79 pairs and consistent non-inferiority decisions. Conclusions: The prespecified blood-loss success criterion was met, whereas operative-time non-inferiority was not demonstrated. Centre confounding, unmodelled within-centre correlation and threshold-based blood-loss recording preclude attribution to the devices alone; the findings contribute hypothesis-generating post-market clinical follow-up evidence.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2026-11-18
DOI
https://doi.org/10.3390/jcm15229053
Primary Topic
Lung Cancer Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Pulmonary Vessel Control During Minimally Invasive Anatomical Lung Resection: A Retrospective Intercentre Comparison of Selective Polymer Clip Use and Stapler-Only Cohorts

Aleksandra Szlachcińska, Maciej Dancewicz, Krzysztof Walczak, Roman Lewandowski
2 links
Journal of Clinical Medicine
Lung Cancer Diagnosis and Treatment
article

Pulmonary Vessel Control During Minimally Invasive Anatomical Lung Resection: A Retrospective Intercentre Comparison of Selective Polymer Clip Use and Stapler-Only Cohorts

Aleksandra Szlachcińska, Maciej Dancewicz, Krzysztof Walczak, Roman Lewandowski
article en

Abstract

Background/Objectives: Comparative evidence for pulmonary vessel control with polymer clips and staplers is limited. We compared selective Click’aV/Click’aV Plus clip use, often combined with vascular stapling, with stapler-only vessel control. Methods: This retrospective intercentre study included adults undergoing minimally invasive lobectomy or segmentectomy at four Polish centres. Two centres contributed each cohort, with no within-centre comparison in the analysed dataset. The prespecified non-inferiority margins were 100 mL for recorded blood loss and 30 min for operative time, tested hierarchically. Qualitative blood-loss records were recoded to their upper thresholds. Results: The analysis included 202 patients: 99 with selective clip use (CLIC) and 103 with stapler-only control (COMP). Threshold entries comprised 64.5% of available CLIC and 51.5% of COMP blood-loss records. The blood-loss criterion was met under upper-threshold recoding (permutation estimate, 36.8 mL; nominal one-sided 95% upper confidence bound, 72.1 mL; p = 0.0016). Operative-time non-inferiority was not demonstrated (difference, 19.3 min; upper bound, 33.9 min; p = 0.1101). Post hoc propensity-score matching yielded 79 pairs and consistent non-inferiority decisions. Conclusions: The prespecified blood-loss success criterion was met, whereas operative-time non-inferiority was not demonstrated. Centre confounding, unmodelled within-centre correlation and threshold-based blood-loss recording preclude attribution to the devices alone; the findings contribute hypothesis-generating post-market clinical follow-up evidence.

Journal of Clinical MedicineVol. 15(22)
Medical University of Silesia (PL), Copernicus Memorial Hospital (PL), Medical University of Lodz (PL), Centrum Onkologii (PL), University of Zielona Góra (PL)
Good health and well-being
Lung Cancer Diagnosis and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon