Internal Model Control-Based Time-Delay Compensation for Small-Signal Stability Improvement in Inverter-Fed Islanded Microgrids

Inverter technology has emerged as a key enabler for renewable energy integration and power delivery in modern microgrids (MGs). Digital time delays associated with measurement, computation, and pulse-width modulation can significantly affect the dynamic performance and stability of islanded inverter-fed microgrids. This paper presents an internal model control (IMC)-based current controller with explicit digital time-delay compensation to improve stability and dynamic performance by addressing delay-induced oscillatory interactions among different control layers. A comprehensive small-signal model is developed by incorporating power, voltage, and current control loops, digital time delay, LC filter, network, and load dynamics. The third-order Padé model of the delay is verified against the exact delay, and system stability is evaluated through eigenvalues, damping ratios and participation factors. At the nominal delay of 15 μs (1.5Ts, Ts=10μs), the current-loop modes of the IMC without compensation are almost undamped (ζ≈0.002) and become unstable beyond 15.25 μs, whereas the proposed controller damps the same modes with ζ=0.29 and remains stable up to 24.75 μs. The proposed design is also compared with a Smith predictor, its robustness to filter, line and load variations is assessed, and particle swarm optimization (PSO) with an explicit stability constraint raises the minimum damping ratio to 0.62. The effectiveness of the proposed approach is verified through comparison with a conventional IMC controller without delay compensation using the OPAL-RT OP4510 real-time simulator, where it reduces the frequency overshoot after load changes from about 30% to below 4% of the steady-state deviation.

Authors

Institutions

Publication Details

Journal
Energies
Published
2026-11-18
DOI
https://doi.org/10.3390/en19225580
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Internal Model Control-Based Time-Delay Compensation for Small-Signal Stability Improvement in Inverter-Fed Islanded Microgrids

Alok Kumar Verma, Pratikanta Mishra, Naresh Kumar Vemula, Muhammad Asif Hasan et al.
2 links
Energies
Microgrid Control and Optimization
article

Internal Model Control-Based Time-Delay Compensation for Small-Signal Stability Improvement in Inverter-Fed Islanded Microgrids

Alok Kumar Verma, Pratikanta Mishra, Naresh Kumar Vemula, Muhammad Asif Hasan, Mohammad Irshad
article en

Abstract

Inverter technology has emerged as a key enabler for renewable energy integration and power delivery in modern microgrids (MGs). Digital time delays associated with measurement, computation, and pulse-width modulation can significantly affect the dynamic performance and stability of islanded inverter-fed microgrids. This paper presents an internal model control (IMC)-based current controller with explicit digital time-delay compensation to improve stability and dynamic performance by addressing delay-induced oscillatory interactions among different control layers. A comprehensive small-signal model is developed by incorporating power, voltage, and current control loops, digital time delay, LC filter, network, and load dynamics. The third-order Padé model of the delay is verified against the exact delay, and system stability is evaluated through eigenvalues, damping ratios and participation factors. At the nominal delay of 15 μs (1.5Ts, Ts=10μs), the current-loop modes of the IMC without compensation are almost undamped (ζ≈0.002) and become unstable beyond 15.25 μs, whereas the proposed controller damps the same modes with ζ=0.29 and remains stable up to 24.75 μs. The proposed design is also compared with a Smith predictor, its robustness to filter, line and load variations is assessed, and particle swarm optimization (PSO) with an explicit stability constraint raises the minimum damping ratio to 0.62. The effectiveness of the proposed approach is verified through comparison with a conventional IMC controller without delay compensation using the OPAL-RT OP4510 real-time simulator, where it reduces the frequency overshoot after load changes from about 30% to below 4% of the steady-state deviation.

EnergiesVol. 19(22)
Agency for Science, Technology and Research (SG), Birla Institute of Technology, Mesra (IN), SRM University (IN), Advanced Remanufacturing & Technology Centre (SG), Saveetha University (IN), National Institute of Technology Meghalaya (IN)
Industry, innovation and infrastructure, Affordable and clean energy
Microgrid Control and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon