Patent Ductus Arteriosus Stenting in Duct-Dependent Pulmonary Blood Flow: Comparison of CT Angiography and Echocardiography for Stent Sizing and Evaluation of Femoral Versus Axillary Access Outcomes
Background: Duct-dependent pulmonary blood flow is a critical neonatal emergency. Patent ductus arteriosus (PDA) stenting is a viable alternative to surgical shunts, but optimal pre-procedural imaging for sizing and the choice of vascular access (femoral vs. axillary) remain debated. Aim: This retrospective study aimed to evaluate the degree of agreement between pre-procedural imaging (CT angiography vs. echocardiography) and the final implanted stent dimensions and to evaluate outcomes associated with femoral versus axillary access. Methods: A retrospective cohort study was conducted at the Queen Alia Heart Institute, Jordan, from January 2020 to May 2024. Medical records of neonates and infants who underwent PDA stenting for duct-dependent pulmonary blood flow were reviewed. Patients were categorized by imaging modality (CT angiography vs. echocardiography) and access approach (femoral vs. axillary). Data collected included demographics, ductal morphology, stent dimensions, procedural details, technical success, complications, and post-procedural outcomes. Results: A total of 48 patients (mean age = 11.2 ± 8.4 days; mean weight = 3.2 ± 0.5 kg) were included. CT angiography (n = 22) demonstrated a numerically smaller mean absolute difference in predicting stent length compared to echocardiography (n = 26) (1.1 mm vs. 2.9 mm; p = 0.006), while diameter agreement was comparable. Axillary access (n = 15) was associated with a shorter procedural time compared to femoral access (n = 33) (49 ± 18 vs. 74 ± 29 minutes; p = 0.003). However, there were no statistically significant differences in technical success (14/15 (93.3%) vs. 25/33 (75.8%); p = 0.239) or major complication rates (2/15 (13.3%) vs. 6/33 (18.2%); p = 1.000). Conclusion: In this small retrospective cohort, CT angiography demonstrated a numerical trend toward better prediction of stent length, and axillary access was associated with shorter procedural times. However, these differences were not statistically significant for technical success or safety outcomes. These findings are hypothesis-generating; larger prospective studies are required to confirm whether tailored imaging and access site selection can improve outcomes in this vulnerable population.
Authors
- Ammar ALghsoon
- Islam Horoub
- Mohammed H Al-Bataineh
- Maisa J Alhalabi
- Amr Almomani
Institutions
- King Hussein Medical Center (JO)
- Armed Forces Hospital (SA)
Publication Details
- Journal
- Cureus
- Published
- 2026-11-17
- DOI
- https://doi.org/10.7759/cureus.119850
- Primary Topic
- Congenital Heart Disease Studies
- Type
- article
- Field-Weighted Citation Impact
- 0.00