Study on Arc Discharge Law and Ablation Characteristics of GIS Basin Insulator Sample Surface Under High Voltage and Large Current

Gas‐insulated metal‐enclosed switchgear (GIS) has emerged as the preferred choice for power grid engineering due to its outstanding performance. However, issues related to arc discharge and thermal damage to basin insulators caused by metal contaminants have become increasingly significant. To investigate the discharge mechanism and thermal damage characteristics, this paper presents the design and construction of a comprehensive test platform for studying the metal arc discharge process on the surface of GIS basin insulators. The research examines the thermal decomposition characteristics, as well as the arc discharge behaviour and ablation characteristics under the combined effects of high voltage and large current. The results show that the insulator has a pyrolysis interval (309.26°C–466.58°C) in an argon atmosphere, and two pyrolysis intervals (307.82°C–472.29°C and 488.15°C–655.65°C) in an air atmosphere. Under the arc ablation effect of the metal wire, black ablation marks are formed on the surface of the sample, and they are classified into four ablation grades through the designed programme. The arc‐initiating charging voltage, ablation area and current action integral on the insulator surface are negatively correlated with the number of metal wires on the surface, whereas the ablation area, current and peak voltage of the insulator surface and current action integral are positively correlated with the test charging voltage. Keep the current action integral of the test circuit consistent, increase the inductance of the test circuit, significantly increase the duration of the ablation arc and decrease the frequency and ablation area. After accumulating 40 ablations, the ablated area on the insulator surface increased significantly, and the upper ablated area was nearly ring‐shaped. The research results provide a reference for ensuring the healthy operation of GIS and prolonging the life of basin insulators.

Authors

Institutions

Publication Details

Journal
High Voltage
Published
2026-11-18
DOI
https://doi.org/10.1049/hve2.70265
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Study on Arc Discharge Law and Ablation Characteristics of GIS Basin Insulator Sample Surface Under High Voltage and Large Current

Yibo Ge, Bingbing Dong, Tong Wen, Mai Wang
3 links
High Voltage
High voltage insulation and dielectric phenomena
article

Study on Arc Discharge Law and Ablation Characteristics of GIS Basin Insulator Sample Surface Under High Voltage and Large Current

Yibo Ge, Bingbing Dong, Tong Wen, Mai Wang
article en

Abstract

Gas‐insulated metal‐enclosed switchgear (GIS) has emerged as the preferred choice for power grid engineering due to its outstanding performance. However, issues related to arc discharge and thermal damage to basin insulators caused by metal contaminants have become increasingly significant. To investigate the discharge mechanism and thermal damage characteristics, this paper presents the design and construction of a comprehensive test platform for studying the metal arc discharge process on the surface of GIS basin insulators. The research examines the thermal decomposition characteristics, as well as the arc discharge behaviour and ablation characteristics under the combined effects of high voltage and large current. The results show that the insulator has a pyrolysis interval (309.26°C–466.58°C) in an argon atmosphere, and two pyrolysis intervals (307.82°C–472.29°C and 488.15°C–655.65°C) in an air atmosphere. Under the arc ablation effect of the metal wire, black ablation marks are formed on the surface of the sample, and they are classified into four ablation grades through the designed programme. The arc‐initiating charging voltage, ablation area and current action integral on the insulator surface are negatively correlated with the number of metal wires on the surface, whereas the ablation area, current and peak voltage of the insulator surface and current action integral are positively correlated with the test charging voltage. Keep the current action integral of the test circuit consistent, increase the inductance of the test circuit, significantly increase the duration of the ablation arc and decrease the frequency and ablation area. After accumulating 40 ablations, the ablated area on the insulator surface increased significantly, and the upper ablated area was nearly ring‐shaped. The research results provide a reference for ensuring the healthy operation of GIS and prolonging the life of basin insulators.

High Voltage
Hefei University of Technology (CN)
Natural Science Foundation of Anhui Province
Industry, innovation and infrastructure, Affordable and clean energy
High voltage insulation and dielectric phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon