A Negative-Index Superlens for Sub-Wavelength Imaging: Resolution, Loss and Bandwidth Budgets from Computed Dispersion
An ordinary lens cannot image detail finer than about half the wavelength, because the fine detail is carried by waves that decay before they reach the image plane. Operating principle: a negative-index superlens, a thin slab whose refractive index is minus one, that amplifies the decaying waves instead of letting them die, so that sub-wavelength detail survives to the image. The superlens resolves features of 60.83 nanometres at a wavelength of 365 nanometres, an improvement factor of 3 over the diffraction limit, with a transmission of 35 percent. The slab recovers detail several times finer than the diffraction limit over a narrow band, which is the capability that makes it a candidate for lithography inspection and for reading features too small for ordinary optics. SIMULATED, NOT MEASURED. This is a computed study for a civilian optics purpose: the device serves imaging, sensing, communications or illumination, and it carries no targeting or weapon application against any person, state or terrestrial object.
Authors
- William Alexander Aldred (ORCID: https://orcid.org/0009-0000-1215-577X)
Publication Details
- Journal
- Zenodo (CERN European Organization for Nuclear Research)
- Published
- 2026-11-18
- DOI
- https://doi.org/10.5281/zenodo.24331544
- Primary Topic
- Metamaterials and Metasurfaces Applications
- Type
- article
- Field-Weighted Citation Impact
- 0.00