Variable Interferences Dictate Different Cutoffs for Aldosterone Measured by Liaison and iSYS Chemiluminescence Immunoassays for the Seated Saline Suppression Test

BACKGROUND: Variable macromolecular-related interferences with different chemiluminescence immunoassays (CLIA) of plasma aldosterone, particularly at low concentrations during confirmatory tests, are a previously unrecognized problem. We therefore hypothesized that cutoffs for measurements of aldosterone for the seated saline suppression test require tailoring according to the particular immunoassay. METHODS: Multicenter study involving 609 patients with suspected primary aldosteronism who underwent seated saline suppression tests with aldosterone measured by liquid chromatography-mass spectrometry (LC-MS/MS) compared with iSYS or Liaison CLIAs in 285 and 286 respective patients and a different LC-MS/MS method in 38 others. Cutoffs for plasma aldosterone were derived from receiver operating characteristic curves after classification of patients with (n=181) and without primary aldosteronism (n=336) by methods independent of confirmatory tests. For 92 patients classifications were not achieved. RESULTS: Youden's-index derived cutoffs for postsaline infusion plasma aldosterone were 300 and 272 pmol/L for measurements by respective Liaison and iSYS CLIAs compared with 169 pmol/L by LC-MS/MS. At those cutoffs, respective diagnostic sensitivities for Liaison and iSYS immunoassays and LC-MS/MS were 90% (CI, 84-97), 91% (CI, 86-97), and 98% (CI, 96-100) with specificities of 86% (CI, 80-91), 94% (CI, 80-91), and 90% (CI, 86-93). Improved disease confirmation according to specificities of 95% for measurements by Liaison and iSYS CLIAs and LC-MS/MS were provided by respective cutoffs of 436, 297, and 243 pmol/L but with reduced sensitivities of 64% (CI, 53-75), 85% (CI, 78-92), and 78% (CI, 72-84). CONCLUSIONS: Cutoffs for CLIA-based measurements of aldosterone during the seated saline suppression test are higher than those for LC-MS/MS and vary according to the specific immunoassay. Gray areas around cutoffs, particularly extensive for the Liaison CLIA, must also be considered. REGISTRATION: https://drks.de/search/en/trial/DRKS00017084.

Authors

Institutions

Publication Details

Journal
Journal of the American Heart Association
Published
2026-11-18
DOI
https://doi.org/10.1161/jaha.126.051573
Primary Topic
Hormonal Regulation and Hypertension
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Variable Interferences Dictate Different Cutoffs for Aldosterone Measured by Liaison and iSYS Chemiluminescence Immunoassays for the Seated Saline Suppression Test

Christina Pamporaki, Hanna Remde, Jacques W.M. Lenders, Felix Beuschlein et al.
1 links
Journal of the American Heart Association
Hormonal Regulation and Hypertension
article

Variable Interferences Dictate Different Cutoffs for Aldosterone Measured by Liaison and iSYS Chemiluminescence Immunoassays for the Seated Saline Suppression Test

Christina Pamporaki, Hanna Remde, Jacques W.M. Lenders, Felix Beuschlein, Martín Reincke, Andrea Rita Horvath, Tracy Ann Williams, Carmina Teresa Fuß, Graeme Eisenhofer, Jun Yang
article en

Abstract

BACKGROUND: Variable macromolecular-related interferences with different chemiluminescence immunoassays (CLIA) of plasma aldosterone, particularly at low concentrations during confirmatory tests, are a previously unrecognized problem. We therefore hypothesized that cutoffs for measurements of aldosterone for the seated saline suppression test require tailoring according to the particular immunoassay. METHODS: Multicenter study involving 609 patients with suspected primary aldosteronism who underwent seated saline suppression tests with aldosterone measured by liquid chromatography-mass spectrometry (LC-MS/MS) compared with iSYS or Liaison CLIAs in 285 and 286 respective patients and a different LC-MS/MS method in 38 others. Cutoffs for plasma aldosterone were derived from receiver operating characteristic curves after classification of patients with (n=181) and without primary aldosteronism (n=336) by methods independent of confirmatory tests. For 92 patients classifications were not achieved. RESULTS: Youden's-index derived cutoffs for postsaline infusion plasma aldosterone were 300 and 272 pmol/L for measurements by respective Liaison and iSYS CLIAs compared with 169 pmol/L by LC-MS/MS. At those cutoffs, respective diagnostic sensitivities for Liaison and iSYS immunoassays and LC-MS/MS were 90% (CI, 84-97), 91% (CI, 86-97), and 98% (CI, 96-100) with specificities of 86% (CI, 80-91), 94% (CI, 80-91), and 90% (CI, 86-93). Improved disease confirmation according to specificities of 95% for measurements by Liaison and iSYS CLIAs and LC-MS/MS were provided by respective cutoffs of 436, 297, and 243 pmol/L but with reduced sensitivities of 64% (CI, 53-75), 85% (CI, 78-92), and 78% (CI, 72-84). CONCLUSIONS: Cutoffs for CLIA-based measurements of aldosterone during the seated saline suppression test are higher than those for LC-MS/MS and vary according to the specific immunoassay. Gray areas around cutoffs, particularly extensive for the Liaison CLIA, must also be considered. REGISTRATION: https://drks.de/search/en/trial/DRKS00017084.

Journal of the American Heart Association
The University of Sydney (AU), University of Zurich (CH), University of Würzburg (DE), Radboud University Medical Center (NL), University Hospital of Zurich (CH), Prince of Wales Hospital (AU), Universitätsklinikum Würzburg (DE), University Hospital Carl Gustav Carus (DE), Monash University (AU), Technische Universität Dresden (DE), Ludwig-Maximilians-Universität München (DE)
Deutsche Forschungsgemeinschaft, Medical Research Future Fund
Good health and well-being
Hormonal Regulation and Hypertension
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon