Short Expandable-Wing Suture Anchors for Tibial Eminence Avulsion Fracture Fixation: Effects of Solid Versus Additively Manufactured Lattice Wings on Biomechanical Performance and Cytocompatibility

Fixation of tibial eminence avulsion fractures (TEAFs) in skeletally immature patients requires adequate mechanical stability within a limited insertion depth to minimize the risk of physeal injury. Conventional transosseous cortical-button fixation (TCBF) requires the creation of tibial bone tunnels, whereas conventional suture anchors may have excessive insertion depths. In our previous study, a short expandable-wing (SEW) suture anchor (9.5 mm in length and 5.5 mm in diameter) with CNC-machined solid wings was developed to enhance fixation strength within a limited bone volume. In the present study, a second-generation SEW anchor was developed by replacing the solid wings with 3D-printed Ti6Al4V lattice wings to provide a potentially more favorable bone–implant interface. The mechanical performance of CNC-SEW and metal additively manufactured SEW (MAM-SEW) anchors was evaluated using polyurethane-block pull-out testing and a porcine TEAF model with single- and double-suture TCBF controls. Cytocompatibility was assessed using an MG-63 direct-contact MTT assay. Pull-out loads were 574.8 ± 10.6 N for CNC-SEW and 501.2 ± 39.2 N for MAM-SEW, compared with 429.0 ± 29.0 N for a historical TWINFIX comparator. After 200 loading cycles in the porcine model, cumulative displacements were 0.9 and 0.7 mm for CNC-SEW and MAM-SEW, respectively, compared with 2.2 and 1.3 mm for single- and double-suture TCBF. The corresponding ultimate failure loads were 278.88 and 292.56 N for the SEW groups, compared with 109.86 and 223.56 N for the TCBF groups. The MAM-SEW group also exhibited higher MG-63 metabolic activity than the CNC-SEW group. These findings demonstrate favorable initial fixation performance and preliminary cytocompatibility of the lattice-wing SEW anchor, supporting its potential application in TEAF fixation. Further studies are required to evaluate long-term osseointegration and physeal safety.

Authors

Institutions

Publication Details

Journal
Journal of Functional Biomaterials
Published
2026-11-18
DOI
https://doi.org/10.3390/jfb17110584
Primary Topic
Bone fractures and treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Short Expandable-Wing Suture Anchors for Tibial Eminence Avulsion Fracture Fixation: Effects of Solid Versus Additively Manufactured Lattice Wings on Biomechanical Performance and Cytocompatibility

Hsuan-Wen Wang, Chun‐Li Lin, Yen Cheng, Chiao-Min Chang et al.
1 links
Journal of Functional Biomaterials
Bone fractures and treatments
article

Short Expandable-Wing Suture Anchors for Tibial Eminence Avulsion Fracture Fixation: Effects of Solid Versus Additively Manufactured Lattice Wings on Biomechanical Performance and Cytocompatibility

Hsuan-Wen Wang, Chun‐Li Lin, Yen Cheng, Chiao-Min Chang, Rong-Chen Lin, Chia-Hung Tsai, Hsu-Wei Lin
article en

Abstract

Fixation of tibial eminence avulsion fractures (TEAFs) in skeletally immature patients requires adequate mechanical stability within a limited insertion depth to minimize the risk of physeal injury. Conventional transosseous cortical-button fixation (TCBF) requires the creation of tibial bone tunnels, whereas conventional suture anchors may have excessive insertion depths. In our previous study, a short expandable-wing (SEW) suture anchor (9.5 mm in length and 5.5 mm in diameter) with CNC-machined solid wings was developed to enhance fixation strength within a limited bone volume. In the present study, a second-generation SEW anchor was developed by replacing the solid wings with 3D-printed Ti6Al4V lattice wings to provide a potentially more favorable bone–implant interface. The mechanical performance of CNC-SEW and metal additively manufactured SEW (MAM-SEW) anchors was evaluated using polyurethane-block pull-out testing and a porcine TEAF model with single- and double-suture TCBF controls. Cytocompatibility was assessed using an MG-63 direct-contact MTT assay. Pull-out loads were 574.8 ± 10.6 N for CNC-SEW and 501.2 ± 39.2 N for MAM-SEW, compared with 429.0 ± 29.0 N for a historical TWINFIX comparator. After 200 loading cycles in the porcine model, cumulative displacements were 0.9 and 0.7 mm for CNC-SEW and MAM-SEW, respectively, compared with 2.2 and 1.3 mm for single- and double-suture TCBF. The corresponding ultimate failure loads were 278.88 and 292.56 N for the SEW groups, compared with 109.86 and 223.56 N for the TCBF groups. The MAM-SEW group also exhibited higher MG-63 metabolic activity than the CNC-SEW group. These findings demonstrate favorable initial fixation performance and preliminary cytocompatibility of the lattice-wing SEW anchor, supporting its potential application in TEAF fixation. Further studies are required to evaluate long-term osseointegration and physeal safety.

Journal of Functional BiomaterialsVol. 17(11)
National Yang Ming Chiao Tung University (TW), Tri-Service General Hospital Songshan Branch (TW), National Defense Medical Center (TW)
Good health and well-being
Bone fractures and treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon