Study on the influence of cathode position on the performance of a low-power magnetically enhanced hollow cathode thruster

To investigate the influence of cathode position on the discharge characteristics, plume characteristics, and propulsion performance of a low-power magnetically enhanced hollow cathode thruster (MHCT), comparative experiments were conducted using center-mounted and externally mounted cathode configurations under different anode voltages and xenon flow rates. The anode current, discharge oscillations, plume ion current density, ion energy distribution, thrust, specific impulse, and thrust efficiency were measured and analyzed. The results show that the center-mounted cathode configuration generally exhibited a higher anode current and could maintain stable discharge at lower anode voltages under low-flow-rate conditions. Compared with the externally mounted cathode configuration, the center-mounted cathode exhibited a higher dominant discharge oscillation frequency and weaker harmonic components. At a total xenon flow rate of 4 sccm, the mass utilization efficiency of the center-mounted cathode configuration reached approximately 58.5%–59.7%, compared with 29.4%–46.4% for the externally mounted cathode configuration. Although the externally mounted cathode produced a higher peak ion current density near the thruster axis and a more concentrated ion beam, the center-mounted cathode generally generated a higher total plume ion current. Retarding potential analyzer measurements at 280 V and 4 sccm revealed relatively low ion energies along the thruster axis for both configurations, with higher ion energies observed in the off-axis regions. The center-mounted cathode configuration generally achieved higher thrust, specific impulse, and thrust efficiency, particularly under low-flow-rate conditions. These results indicate that cathode position affects the coupling between the cathode and the main discharge region, as well as ion production and acceleration, thereby influencing the overall propulsion performance of the MHCT.

Authors

Institutions

Publication Details

Journal
Plasma Science and Technology
Published
2026-11-19
DOI
https://doi.org/10.1088/2058-6272/aec41e
Primary Topic
Low-Pressure Plasma Processing and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Study on the influence of cathode position on the performance of a low-power magnetically enhanced hollow cathode thruster

Zhongxi Ning, Yue Wang, Dongyang Zhang
1 links
Plasma Science and Technology
Low-Pressure Plasma Processing and Diagnostics
article

Study on the influence of cathode position on the performance of a low-power magnetically enhanced hollow cathode thruster

Zhongxi Ning, Yue Wang, Dongyang Zhang
article en

Abstract

To investigate the influence of cathode position on the discharge characteristics, plume characteristics, and propulsion performance of a low-power magnetically enhanced hollow cathode thruster (MHCT), comparative experiments were conducted using center-mounted and externally mounted cathode configurations under different anode voltages and xenon flow rates. The anode current, discharge oscillations, plume ion current density, ion energy distribution, thrust, specific impulse, and thrust efficiency were measured and analyzed. The results show that the center-mounted cathode configuration generally exhibited a higher anode current and could maintain stable discharge at lower anode voltages under low-flow-rate conditions. Compared with the externally mounted cathode configuration, the center-mounted cathode exhibited a higher dominant discharge oscillation frequency and weaker harmonic components. At a total xenon flow rate of 4 sccm, the mass utilization efficiency of the center-mounted cathode configuration reached approximately 58.5%–59.7%, compared with 29.4%–46.4% for the externally mounted cathode configuration. Although the externally mounted cathode produced a higher peak ion current density near the thruster axis and a more concentrated ion beam, the center-mounted cathode generally generated a higher total plume ion current. Retarding potential analyzer measurements at 280 V and 4 sccm revealed relatively low ion energies along the thruster axis for both configurations, with higher ion energies observed in the off-axis regions. The center-mounted cathode configuration generally achieved higher thrust, specific impulse, and thrust efficiency, particularly under low-flow-rate conditions. These results indicate that cathode position affects the coupling between the cathode and the main discharge region, as well as ion production and acceleration, thereby influencing the overall propulsion performance of the MHCT.

Plasma Science and Technology
Harbin Institute of Technology (CN)
Affordable and clean energy
Low-Pressure Plasma Processing and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon