A transformer analysis lowers the energy threshold and improves the sensitivity of a compact imaging atmospheric Cherenkov telescope

Context. A companion study simulated an idealised stand-alone imaging atmospheric Cherenkov telescope with a 5 m diameter mirror. A video vision transformer that processes the raw camera waveforms lowered its energy threshold by a factor of three, compared with the standard analysis based on image parameters. Aims. We use realistic photodetectors, compute the differential flux sensitivity, and study how hardware parameters affect the transformer analysis. Methods. With the simulation tools of the Cherenkov Telescope Array Observatory, we compare three photodetector efficiencies (100 %, 50 % and that of the LST-1 photomultipliers) with the transformer and with a standard analysis optimised for each. We then vary the dish diameter, field of view, pulse width and sampling rate. Results. With the LST-1 photomultipliers, the energy threshold is 0.18 TeV with the transformer and 0.73 TeV with the standard analysis. The standard analysis needs a photodetector efficiency of 100 % to match that threshold. The main reason is that the transformer works with events of about 35 photoelectrons in the camera, whereas the standard analysis needs about 200 before image cleaning. A 4 m dish with the transformer is more sensitive at all energies than a 5 m dish with the standard analysis. Dishes of 4, 5 and 6 m diameter give thresholds of 0.38, 0.18 and 0.13 TeV. Sampling the pixel signals at 2 GS/s instead of 5 GS/s raises the threshold to 0.26 TeV, whereas the single-photoelectron pulse width (1-3 ns) matters little. Conclusions. The analysis matters as much as the mirror area and the photodetector efficiency. With the transformer analysis, the idealised 5 m diameter telescope comes within a factor of about four of the sensitivity of LST-1 and MAGIC above 0.25 TeV, although its mirror area is 21 times smaller than that of the 23 m LST-1. This performance should improve substantially in the coming years.

Authors

Publication Details

Journal
arXiv (Cornell University)
Published
2026-11-17
DOI
https://doi.org/10.48550/arxiv.2611.23047
Primary Topic
Astrophysics and Cosmic Phenomena
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

A transformer analysis lowers the energy threshold and improves the sensitivity of a compact imaging atmospheric Cherenkov telescope

Elli Jobst, David Paneque, Lukas Heinrich
arXiv (Cornell University)
Astrophysics and Cosmic Phenomena
preprint

A transformer analysis lowers the energy threshold and improves the sensitivity of a compact imaging atmospheric Cherenkov telescope

Elli Jobst, David Paneque, Lukas Heinrich
preprint en

Abstract

Context. A companion study simulated an idealised stand-alone imaging atmospheric Cherenkov telescope with a 5 m diameter mirror. A video vision transformer that processes the raw camera waveforms lowered its energy threshold by a factor of three, compared with the standard analysis based on image parameters. Aims. We use realistic photodetectors, compute the differential flux sensitivity, and study how hardware parameters affect the transformer analysis. Methods. With the simulation tools of the Cherenkov Telescope Array Observatory, we compare three photodetector efficiencies (100 %, 50 % and that of the LST-1 photomultipliers) with the transformer and with a standard analysis optimised for each. We then vary the dish diameter, field of view, pulse width and sampling rate. Results. With the LST-1 photomultipliers, the energy threshold is 0.18 TeV with the transformer and 0.73 TeV with the standard analysis. The standard analysis needs a photodetector efficiency of 100 % to match that threshold. The main reason is that the transformer works with events of about 35 photoelectrons in the camera, whereas the standard analysis needs about 200 before image cleaning. A 4 m dish with the transformer is more sensitive at all energies than a 5 m dish with the standard analysis. Dishes of 4, 5 and 6 m diameter give thresholds of 0.38, 0.18 and 0.13 TeV. Sampling the pixel signals at 2 GS/s instead of 5 GS/s raises the threshold to 0.26 TeV, whereas the single-photoelectron pulse width (1-3 ns) matters little. Conclusions. The analysis matters as much as the mirror area and the photodetector efficiency. With the transformer analysis, the idealised 5 m diameter telescope comes within a factor of about four of the sensitivity of LST-1 and MAGIC above 0.25 TeV, although its mirror area is 21 times smaller than that of the 23 m LST-1. This performance should improve substantially in the coming years.

arXiv (Cornell University)
Astrophysics and Cosmic Phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon