A State-Level Assessment of Space Weather Impact on the Virginia Power Grid: From Vulnerability to Mitigation Strategies

Contemporary methodologies exist for assessing the nationwide impacts of geomagnetically induced currents (GICs), such as the Coupled Space Weather Impact Model (C-SWIM), which links power grid vulnerability with economic losses. Yet regional mitigation requires adapting the national model to the local transmission network so operators and planners can identify substations at risk and evaluate economic and population consequences and protective actions. We present the first adaptation of C-SWIM to Virginia, modeling the Pennsylvania–New Jersey–Maryland (PJM) Interconnection, which includes Dominion Energy Virginia and Appalachian Power. Its extra high voltage network was assessed under the May 2024 Gannon, October 2003 Halloween, and March 2015 St. Patrick’s Day storms in addition to nine return period scenarios derived from statistical fits to 92 historical events. Using the Leontief consumption and production input–output model, we estimated daily losses of $145.5M for a 100-year storm and $230.6M for a 250-year storm, with 339,000–535,000 people and up to 12,000 businesses at risk of power outage. Furthermore, the Ghosh input–output model was used to evaluate three island selection algorithms for protective islanding, which temporarily disconnects parts of the grid to reduce transformer damage. Only one algorithm yielded benefits exceeding costs across all twelve scenarios, with avoided losses up to $9.69M per day and a cost of $0.204M per intervention. However, these islanding benefits assume disconnection for 6 hours and transformer replacement after 365 days. Moreover, the analysis uses national economic relationships and models only transformer thermal failure, excluding voltage collapse, cascading failures, and restoration. Transmission operators and state energy policymakers can use this statewide assessment to prioritize regional monitoring and appraise protective islanding.

Authors

Publication Details

Journal
EarthArXiv (California Digital Library)
Published
2026-11-18
DOI
https://doi.org/10.31223/x5fv5z
Primary Topic
Ionosphere and magnetosphere dynamics
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

A State-Level Assessment of Space Weather Impact on the Virginia Power Grid: From Vulnerability to Mitigation Strategies

Vedaang Verma, Edward Oughton, Lucy Wilkerson, Dennies Bor
2 links
EarthArXiv (California Digital Library)
Ionosphere and magnetosphere dynamics
preprint

A State-Level Assessment of Space Weather Impact on the Virginia Power Grid: From Vulnerability to Mitigation Strategies

Vedaang Verma, Edward Oughton, Lucy Wilkerson, Dennies Bor
preprint en

Abstract

Contemporary methodologies exist for assessing the nationwide impacts of geomagnetically induced currents (GICs), such as the Coupled Space Weather Impact Model (C-SWIM), which links power grid vulnerability with economic losses. Yet regional mitigation requires adapting the national model to the local transmission network so operators and planners can identify substations at risk and evaluate economic and population consequences and protective actions. We present the first adaptation of C-SWIM to Virginia, modeling the Pennsylvania–New Jersey–Maryland (PJM) Interconnection, which includes Dominion Energy Virginia and Appalachian Power. Its extra high voltage network was assessed under the May 2024 Gannon, October 2003 Halloween, and March 2015 St. Patrick’s Day storms in addition to nine return period scenarios derived from statistical fits to 92 historical events. Using the Leontief consumption and production input–output model, we estimated daily losses of $145.5M for a 100-year storm and $230.6M for a 250-year storm, with 339,000–535,000 people and up to 12,000 businesses at risk of power outage. Furthermore, the Ghosh input–output model was used to evaluate three island selection algorithms for protective islanding, which temporarily disconnects parts of the grid to reduce transformer damage. Only one algorithm yielded benefits exceeding costs across all twelve scenarios, with avoided losses up to $9.69M per day and a cost of $0.204M per intervention. However, these islanding benefits assume disconnection for 6 hours and transformer replacement after 365 days. Moreover, the analysis uses national economic relationships and models only transformer thermal failure, excluding voltage collapse, cascading failures, and restoration. Transmission operators and state energy policymakers can use this statewide assessment to prioritize regional monitoring and appraise protective islanding.

EarthArXiv (California Digital Library)
Industry, innovation and infrastructure, Affordable and clean energy, Climate action
Ionosphere and magnetosphere dynamics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon