Experimental and theoretical exploration of gamma-ray attenuation in Fe, Co, Gd and Nd at selected photon energies

This study investigated the attenuation capability of selected high-Z elemental metals, namely iron, cobalt, gadolinium, and neodymium, against γ-rays by evaluating their photon-interaction and shielding parameters. The mass attenuation coefficient, linear attenuation coefficient, total atomic cross-section, molar extinction coefficient, half-value layer, tenth-value layer, mean free path, and radiation protection efficiency were determined in this study. The mass attenuation coefficient (MAC) was measured using a well-geometry γ-ray system equipped with a NaI(Tl) scintillation detector over the photon-energy range of 122-1330 keV and compared with theoretical values obtained from the XCOM database. The experimental and theoretical MAC values showed reasonable agreement across the selected energy range, with relative deviations within ±8%. The experimental MAC values decreased from 0.2483 to 0.0539 cm2/g for Fe, from 0.2986 to 0.0526 cm2/g for Co, from 1.7988 to 0.0538 cm2/g for Gd, and from 1.7250 to 0.0518 cm2/g for Nd as the photon energy increased from 122 to 1330 keV. At a fixed sample thickness of 0.5 cm, Gd exhibited the highest RPE in the low-energy range of 122-662 keV, reaching a maximum of 87.6633%, whereas Co exhibited the highest RPE in the higher-energy range of 840-1330 keV, with a maximum value of 33.5426%. Overall, the obtained results demonstrate the energy-dependent and effective γ-ray attenuation performance of the investigated high-Z elemental metals and indicate their potential use in radiation shielding and radiological protection applications.

Authors

Institutions

Publication Details

Journal
Journal of Radiological Protection
Published
2026-11-18
DOI
https://doi.org/10.1088/1361-6498/aec3b0
Primary Topic
Radiation Shielding Materials Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Experimental and theoretical exploration of gamma-ray attenuation in Fe, Co, Gd and Nd at selected photon energies

Hassan Al Kanti, Abdu Hamoud Al-khawlany, Fawziah Mohammad Al-Saar
1 links
Journal of Radiological Protection
Radiation Shielding Materials Analysis
article

Experimental and theoretical exploration of gamma-ray attenuation in Fe, Co, Gd and Nd at selected photon energies

Hassan Al Kanti, Abdu Hamoud Al-khawlany, Fawziah Mohammad Al-Saar
article en

Abstract

This study investigated the attenuation capability of selected high-Z elemental metals, namely iron, cobalt, gadolinium, and neodymium, against γ-rays by evaluating their photon-interaction and shielding parameters. The mass attenuation coefficient, linear attenuation coefficient, total atomic cross-section, molar extinction coefficient, half-value layer, tenth-value layer, mean free path, and radiation protection efficiency were determined in this study. The mass attenuation coefficient (MAC) was measured using a well-geometry γ-ray system equipped with a NaI(Tl) scintillation detector over the photon-energy range of 122-1330 keV and compared with theoretical values obtained from the XCOM database. The experimental and theoretical MAC values showed reasonable agreement across the selected energy range, with relative deviations within ±8%. The experimental MAC values decreased from 0.2483 to 0.0539 cm2/g for Fe, from 0.2986 to 0.0526 cm2/g for Co, from 1.7988 to 0.0538 cm2/g for Gd, and from 1.7250 to 0.0518 cm2/g for Nd as the photon energy increased from 122 to 1330 keV. At a fixed sample thickness of 0.5 cm, Gd exhibited the highest RPE in the low-energy range of 122-662 keV, reaching a maximum of 87.6633%, whereas Co exhibited the highest RPE in the higher-energy range of 840-1330 keV, with a maximum value of 33.5426%. Overall, the obtained results demonstrate the energy-dependent and effective γ-ray attenuation performance of the investigated high-Z elemental metals and indicate their potential use in radiation shielding and radiological protection applications.

Journal of Radiological Protection
Amran University (YE)
Radiation Shielding Materials Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon