A Superconducting Transition-Edge Bolometer Photon Counter: Saturation, Noise Equivalent Power and Count-Rate Budgets from Computed Thermal Physics

Measuring the power of a faint stream of photons one by one needs a bolometer that warms measurably when a photon arrives, and the bolometer must be sized so that its saturation, its noise floor and its recovery time all serve the measurement. Operating principle: a superconducting transition-edge bolometer, a superconducting film on a weak thermal link, in which one absorbed photon warms the film on its resistive transition and the resulting current pulse measures the photon while the thermal link sets the recovery. The transition-edge bolometer resolves photon energy to 0.2 electronvolts at a wavelength of 1550 nanometres, with a detection efficiency of 90 percent and a saturation energy of 10 electronvolts. The bolometer counts photons with an energy resolution of two tenths of an electronvolt while its noise floor sits far below a single photon, which is the sensitivity that makes faint-power measurements at the quantum level possible. SIMULATED, NOT MEASURED. This is a computed study for a civilian sensing purpose: the device serves imaging, sensing, communications or illumination, and it carries no targeting or weapon application against any person, state or terrestrial object.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-18
DOI
https://doi.org/10.5281/zenodo.24336837
Primary Topic
Superconducting and THz Device Technology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A Superconducting Transition-Edge Bolometer Photon Counter: Saturation, Noise Equivalent Power and Count-Rate Budgets from Computed Thermal Physics

William Alexander Aldred
6 links
Zenodo (CERN European Organization for Nuclear Research)
Superconducting and THz Device Technology
article

A Superconducting Transition-Edge Bolometer Photon Counter: Saturation, Noise Equivalent Power and Count-Rate Budgets from Computed Thermal Physics

William Alexander Aldred
article en

Abstract

Measuring the power of a faint stream of photons one by one needs a bolometer that warms measurably when a photon arrives, and the bolometer must be sized so that its saturation, its noise floor and its recovery time all serve the measurement. Operating principle: a superconducting transition-edge bolometer, a superconducting film on a weak thermal link, in which one absorbed photon warms the film on its resistive transition and the resulting current pulse measures the photon while the thermal link sets the recovery. The transition-edge bolometer resolves photon energy to 0.2 electronvolts at a wavelength of 1550 nanometres, with a detection efficiency of 90 percent and a saturation energy of 10 electronvolts. The bolometer counts photons with an energy resolution of two tenths of an electronvolt while its noise floor sits far below a single photon, which is the sensitivity that makes faint-power measurements at the quantum level possible. SIMULATED, NOT MEASURED. This is a computed study for a civilian sensing purpose: the device serves imaging, sensing, communications or illumination, and it carries no targeting or weapon application against any person, state or terrestrial object.

Zenodo (CERN European Organization for Nuclear Research)
Superconducting and THz Device Technology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon