Sparse-View CT Reconstruction Using Deep Learning

Sparse-view computed tomography (CT) reduces radiation dose and scan time by acquiring few projection angles but filtered back-projection (FBP) of such data suffers from severe streak artefacts because the angular sampling falls far below the Nyquist requirement. We study the post-processing approach in which a residual U-Net removes these artefacts from the FBP image, and test it on five synthetic datasets that differ in object class and physics: head phantoms at normal dose, chest phantoms at ten-fold lower dose, aluminium machined parts, photon-starved titanium components, and aluminium resolution targets. Sinograms at 30, 60 and 90 views are simulated with the Beer-Lambert law, Poisson photon statistics and Gaussian read noise, and the network is compared against FBP and the Simultaneous Algebraic Reconstruction Technique (SART), both with settings tuned on validation data. On 150 held-out test images per dataset, the U-Net achieves the highest peak signal-to-noise ratio (PSNR) in all 15 dataset and view settings, improving on the best classical method by 1.9 to 5.8 dB (paired Wilcoxon test, p < 10⁻²⁰ in every setting), and at 30 views it exceeds the PSNR of 180-view FBP on all five datasets, while running in about 20 ms per image on a CPU. Stress tests show the limits of the approach: networks transfer between similar industrial datasets but degrade or harm images of other object classes, fail when the test data are more sparsely sampled or receive ten times fewer photons than in training, and are outperformed by SART on the unseen Shepp-Logan phantom. A network trained on resolution targets does generalise to a resolution plate taken from laboratory data, improving on SART by 2.7 to 3.4 dB. The code, data and trained models are released for full reproducibility.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-18
DOI
https://doi.org/10.21203/rs.3.rs-11733389/v1
Primary Topic
Medical Imaging Techniques and Applications
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Sparse-View CT Reconstruction Using Deep Learning

Mayank Goswami, Suthar Het Nileshbhai1
Research Square
Medical Imaging Techniques and Applications
preprint

Sparse-View CT Reconstruction Using Deep Learning

Mayank Goswami, Suthar Het Nileshbhai1
preprint en

Abstract

Sparse-view computed tomography (CT) reduces radiation dose and scan time by acquiring few projection angles but filtered back-projection (FBP) of such data suffers from severe streak artefacts because the angular sampling falls far below the Nyquist requirement. We study the post-processing approach in which a residual U-Net removes these artefacts from the FBP image, and test it on five synthetic datasets that differ in object class and physics: head phantoms at normal dose, chest phantoms at ten-fold lower dose, aluminium machined parts, photon-starved titanium components, and aluminium resolution targets. Sinograms at 30, 60 and 90 views are simulated with the Beer-Lambert law, Poisson photon statistics and Gaussian read noise, and the network is compared against FBP and the Simultaneous Algebraic Reconstruction Technique (SART), both with settings tuned on validation data. On 150 held-out test images per dataset, the U-Net achieves the highest peak signal-to-noise ratio (PSNR) in all 15 dataset and view settings, improving on the best classical method by 1.9 to 5.8 dB (paired Wilcoxon test, p < 10⁻²⁰ in every setting), and at 30 views it exceeds the PSNR of 180-view FBP on all five datasets, while running in about 20 ms per image on a CPU. Stress tests show the limits of the approach: networks transfer between similar industrial datasets but degrade or harm images of other object classes, fail when the test data are more sparsely sampled or receive ten times fewer photons than in training, and are outperformed by SART on the unseen Shepp-Logan phantom. A network trained on resolution targets does generalise to a resolution plate taken from laboratory data, improving on SART by 2.7 to 3.4 dB. The code, data and trained models are released for full reproducibility.

Research Square
Indian Institute of Technology Roorkee (IN)
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon