A soft computing-based technique of power network reconfiguration to reduce active power loss and improvement of voltage profile for quantifying power system resiliency

In a power network, loadability limit and active power loss are important parameters for the operating personnel. The network reconfiguration technique is more suitable than conventional techniques to curb the active power loss to an optimized level and maintain a good voltage profile, as reactive power support is relatively less and gives promising results. Furthermore, high-impact catastrophes such as hurricanes, earthquakes, and fires may make load restoration more difficult due to power network outages from the upstream grid or concurrent component failures. The proposed method is implemented on the IEEE-14 bus and IEEE-33 bus distribution systems. The goal of this research is to offer a soft computing-based effective approach to network reconfiguration in order to reduce active power loss in lines and increase voltage magnitude at buses. This article presents a binary particle swarm optimization-based network reconfiguration framework for minimizing active power loss, improving voltage profile, and enhancing power system resiliency under contingency conditions. For the IEEE 14-bus system, the proposed method achieves a 28.43% reduction in active power loss, along with an improvement in minimum bus voltage from 0.9247 to 0.9433 p.u. For the IEEE 33-bus system, power loss is reduced from 208.46 to 143.31 kW (31.25%), and further to 138.93 kW (33.35%) with optimal DG integration. The minimum voltage is improved from 0.9107 to 0.9423 p.u. Comparative analysis with existing literature demonstrates the effectiveness and robustness of the proposed method. The results confirm that the integrated reconfiguration and distributed generation strategy significantly enhances both operational efficiency and system resiliency.

Authors

Institutions

Publication Details

Journal
International Journal of Electrical Engineering Education
Published
2026-11-18
DOI
https://doi.org/10.1177/00207209261508574
Primary Topic
Optimal Power Flow Distribution
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A soft computing-based technique of power network reconfiguration to reduce active power loss and improvement of voltage profile for quantifying power system resiliency

Dipanjan Bose, Chandan Kumar Chanda
International Journal of Electrical Engineering Education
Optimal Power Flow Distribution
article

A soft computing-based technique of power network reconfiguration to reduce active power loss and improvement of voltage profile for quantifying power system resiliency

Dipanjan Bose, Chandan Kumar Chanda
article en

Abstract

In a power network, loadability limit and active power loss are important parameters for the operating personnel. The network reconfiguration technique is more suitable than conventional techniques to curb the active power loss to an optimized level and maintain a good voltage profile, as reactive power support is relatively less and gives promising results. Furthermore, high-impact catastrophes such as hurricanes, earthquakes, and fires may make load restoration more difficult due to power network outages from the upstream grid or concurrent component failures. The proposed method is implemented on the IEEE-14 bus and IEEE-33 bus distribution systems. The goal of this research is to offer a soft computing-based effective approach to network reconfiguration in order to reduce active power loss in lines and increase voltage magnitude at buses. This article presents a binary particle swarm optimization-based network reconfiguration framework for minimizing active power loss, improving voltage profile, and enhancing power system resiliency under contingency conditions. For the IEEE 14-bus system, the proposed method achieves a 28.43% reduction in active power loss, along with an improvement in minimum bus voltage from 0.9247 to 0.9433 p.u. For the IEEE 33-bus system, power loss is reduced from 208.46 to 143.31 kW (31.25%), and further to 138.93 kW (33.35%) with optimal DG integration. The minimum voltage is improved from 0.9107 to 0.9423 p.u. Comparative analysis with existing literature demonstrates the effectiveness and robustness of the proposed method. The results confirm that the integrated reconfiguration and distributed generation strategy significantly enhances both operational efficiency and system resiliency.

International Journal of Electrical Engineering Education
Indian Institute of Social Welfare and Business Management (IN)
Industry, innovation and infrastructure, Affordable and clean energy
Optimal Power Flow Distribution
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon