Comparisons of seismocardiographic sensor positions for VO 2 max estimations

VO 2 max is a key health indicator of cardiorespiratory fitness and overall physical performance. VO 2 max can be estimated using seismocardiography (SCG). SCG can be measured at multiple anatomical locations. The xiphoid process (XP) has primarily been used for VO 2 max estimation, and the comparative performance of alternative sensor locations has not been evaluated. The aim of this study was to determine whether SCG sensor locations other than the XP produce systematically different VO 2 max estimates when the same estimation algorithm is applied. The study included 13 healthy male participants. SCG signals were sampled from a 4 × 4 grid of accelerometers, resulting in 16 different sensor locations across the chest, including the XP. VO 2 max was estimated using a previously validated non-exercise SCG algorithm based on fiducial SCG features and demographic variables. Differences in estimated VO 2 max between each sensor location and the XP reference were analysed using a linear mixed-effects model, and Pearson's correlation coefficients were calculated to assess the relationship between sample locations. The analysis showed that seven sensor locations differed significantly from the XP reference, with mean deviations ranging from 1.108 to 2.626 ml·kg⁻¹·min⁻¹. All correlations were greater than 0.849, indicating high consistency between estimates. Bland–Altman analyses demonstrated small mean biases ranging from −2.47 to 2.03 ml·kg⁻¹·min⁻¹ and no evidence of proportional bias for any sensor location, although the limits of agreement indicated some variability at the individual level. VO 2 max estimates showed the strongest agreement with the XP reference at the right thorax, left sternum, and lower left thorax overlying the cardiac silhouette compared with the remaining measurement locations. These findings suggest that several alternative SCG sensor locations provide VO 2 max estimates comparable to the standard XP location, whereas a limited number of locations produce systematic differences and may require location-specific correction before clinical implementation.

Authors

Institutions

Publication Details

Journal
Biomedical Physics & Engineering Express
Published
2026-11-18
DOI
https://doi.org/10.1088/2057-1976/aec3ab
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Comparisons of seismocardiographic sensor positions for VO 2 max estimations

Samuel Emil Schmidt, Ahmad Agam, Rasmus Gundorff Sæderup, Peter Søgaard et al.
2 links
Biomedical Physics & Engineering Express
Non-Invasive Vital Sign Monitoring
article

Comparisons of seismocardiographic sensor positions for VO 2 max estimations

Samuel Emil Schmidt, Ahmad Agam, Rasmus Gundorff Sæderup, Peter Søgaard, Emil Korsgaard, Julie Kathrine Dittmann Kathrine Dittmann Andreasen, Joan Hentze, Sofie Braun Svensen
article en

Abstract

VO 2 max is a key health indicator of cardiorespiratory fitness and overall physical performance. VO 2 max can be estimated using seismocardiography (SCG). SCG can be measured at multiple anatomical locations. The xiphoid process (XP) has primarily been used for VO 2 max estimation, and the comparative performance of alternative sensor locations has not been evaluated. The aim of this study was to determine whether SCG sensor locations other than the XP produce systematically different VO 2 max estimates when the same estimation algorithm is applied. The study included 13 healthy male participants. SCG signals were sampled from a 4 × 4 grid of accelerometers, resulting in 16 different sensor locations across the chest, including the XP. VO 2 max was estimated using a previously validated non-exercise SCG algorithm based on fiducial SCG features and demographic variables. Differences in estimated VO 2 max between each sensor location and the XP reference were analysed using a linear mixed-effects model, and Pearson's correlation coefficients were calculated to assess the relationship between sample locations. The analysis showed that seven sensor locations differed significantly from the XP reference, with mean deviations ranging from 1.108 to 2.626 ml·kg⁻¹·min⁻¹. All correlations were greater than 0.849, indicating high consistency between estimates. Bland–Altman analyses demonstrated small mean biases ranging from −2.47 to 2.03 ml·kg⁻¹·min⁻¹ and no evidence of proportional bias for any sensor location, although the limits of agreement indicated some variability at the individual level. VO 2 max estimates showed the strongest agreement with the XP reference at the right thorax, left sternum, and lower left thorax overlying the cardiac silhouette compared with the remaining measurement locations. These findings suggest that several alternative SCG sensor locations provide VO 2 max estimates comparable to the standard XP location, whereas a limited number of locations produce systematic differences and may require location-specific correction before clinical implementation.

Biomedical Physics & Engineering Express
Aalborg University Hospital (DK), Aalborg University (DK)
Good health and well-being
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon