Development and Validation of a Reproducible Cross-Species Liver Machine Perfusion Platform in Rats and Mice

Ex vivo liver machine perfusion is increasingly used for graft assessment and reconditioning, but reproducible small-animal platforms remain limited. We developed a modular rat-mouse liver machine perfusion platform built around a shared extracorporeal circuit backbone with interchangeable cannulation interfaces, continuous inflow pressure monitoring, and a compact dry thermal-bead bath supporting benchtop subnormothermic and normothermic studies as well as cold-room hypothermic deployment. Performance was assessed by methylene blue perfusion mapping with pixel-based quantification and by blinded Suzuki histologic injury scoring. In mice, the portal cannulation site within the superior mesenteric vein-portal segment determined the completeness of whole-organ perfusion; positioning the cannula distal to the gastric/splenic/pancreatic tributary and proximal to the inferior pancreaticoduodenal vein ensured homogeneous lobar perfusion. In rats, single portal inflow left peripheral lobar regions relatively underperfused, whereas dual portal venous plus hepatic arterial inflow produced the most uniform perfusion (perfused surface area 58-75% vs. 100%). Histology showed preserved architecture on liver biopsies, with total Suzuki scores of 0-1 of 12 across procurement baseline, immediate perfusion, and cold storage plus reperfusion groups. Reproducible whole-organ perfusion demonstrated depends on species-specific vascular access. The current platform was validated for perfusion adequacy and short-term structural preservation; metabolically sustained support and functional viability remain to be demonstrated.

Authors

Institutions

Publication Details

Journal
ASAIO Journal
Published
2026-11-18
DOI
https://doi.org/10.1097/mat.0000000000002922
Primary Topic
Organ Transplantation Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Development and Validation of a Reproducible Cross-Species Liver Machine Perfusion Platform in Rats and Mice

Jill Ann Helms, Andrea J. Reitsma, Olivia M. Martinez, Sheri M. Krams et al.
1 links
ASAIO Journal
Organ Transplantation Techniques and Outcomes
article

Development and Validation of a Reproducible Cross-Species Liver Machine Perfusion Platform in Rats and Mice

Jill Ann Helms, Andrea J. Reitsma, Olivia M. Martinez, Sheri M. Krams, Joshua Sam Badshah, Pamela O. Emengo, 韩述岭, Ryan M. Lee, Varvara A. Kirchner, Justin R. Sleasman, James Dunn, Fabiana Aellos, George P. Zhou, Tetsuya Tajima, Marc L. Melcher, Greta Cywińska, Bo Liu
article en

Abstract

Ex vivo liver machine perfusion is increasingly used for graft assessment and reconditioning, but reproducible small-animal platforms remain limited. We developed a modular rat-mouse liver machine perfusion platform built around a shared extracorporeal circuit backbone with interchangeable cannulation interfaces, continuous inflow pressure monitoring, and a compact dry thermal-bead bath supporting benchtop subnormothermic and normothermic studies as well as cold-room hypothermic deployment. Performance was assessed by methylene blue perfusion mapping with pixel-based quantification and by blinded Suzuki histologic injury scoring. In mice, the portal cannulation site within the superior mesenteric vein-portal segment determined the completeness of whole-organ perfusion; positioning the cannula distal to the gastric/splenic/pancreatic tributary and proximal to the inferior pancreaticoduodenal vein ensured homogeneous lobar perfusion. In rats, single portal inflow left peripheral lobar regions relatively underperfused, whereas dual portal venous plus hepatic arterial inflow produced the most uniform perfusion (perfused surface area 58-75% vs. 100%). Histology showed preserved architecture on liver biopsies, with total Suzuki scores of 0-1 of 12 across procurement baseline, immediate perfusion, and cold storage plus reperfusion groups. Reproducible whole-organ perfusion demonstrated depends on species-specific vascular access. The current platform was validated for perfusion adequacy and short-term structural preservation; metabolically sustained support and functional viability remain to be demonstrated.

ASAIO Journal
Lucile Packard Children's Hospital (US), Stanford Medicine (US), Stanford University (US)
Good health and well-being
Organ Transplantation Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon