Clinical and Radiographic Outcomes of Two Composite Bone Grafts in Transcrestal Sinus Floor Elevation Using Osseodensification: A Randomized Controlled Trial

Objective To compare the osteogenic efficacy and safety of allogeneic bone collagen combined with allogeneic bone graft versus collagen combined with xenogeneic bone graft in osseodensification-assisted transcrestal sinus floor elevation (TSFE), and to investigate the impact of sinus width (SW) and sinus angle (SA) on bone augmentation outcomes. Materials and Methods In this randomized controlled trial, 34 patients were randomly allocated to a test group (n = 17) and a control group (n = 17). All patients underwent TSFE assisted by osseodensification drills. Intraoperatively, allogeneic bone collagen (test group) and collagen (control group) were used as a basal layer to protect the sinus membrane. Six months postoperatively, implant stability was evaluated using resonance frequency analysis (RFA) from four directions. Cone-beam computed tomography (CBCT) data were acquired at baseline, immediately postoperatively, and at 6 months to comparatively analyze bone augmentation parameters. Results No sinus membrane perforations occurred during surgery in either group. At 6 months postoperatively, the implant stability quotient (ISQ) values measured from four directions were all above 80 in both groups, with no statistically significant differences between the groups ( P > 0.05). Regarding bone augmentation, the test group demonstrated significantly superior vertical bone gain (VBG) (6.37 ± 1.11 mm) compared to the control group (5.13 ± 0.93 mm; P = 0.001). Although the graft resorption (GR) was slightly lower in the test group (1.51 ± 0.58 mm) compared to the control group (1.95 ± 1.03 mm), the difference was not statistically significant. Furthermore, statistical analysis confirmed no significant correlation between the 6-month bone augmentation outcomes and SW or SA. Conclusions

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-18
DOI
https://doi.org/10.21203/rs.3.rs-11475673/v1
Primary Topic
Dental Implant Techniques and Outcomes
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Clinical and Radiographic Outcomes of Two Composite Bone Grafts in Transcrestal Sinus Floor Elevation Using Osseodensification: A Randomized Controlled Trial

MO Anchun, Yuzhang Feng, Xiaoqing Zhang
6 links
Research Square
Dental Implant Techniques and Outcomes
preprint

Clinical and Radiographic Outcomes of Two Composite Bone Grafts in Transcrestal Sinus Floor Elevation Using Osseodensification: A Randomized Controlled Trial

MO Anchun, Yuzhang Feng, Xiaoqing Zhang
preprint en

Abstract

Objective To compare the osteogenic efficacy and safety of allogeneic bone collagen combined with allogeneic bone graft versus collagen combined with xenogeneic bone graft in osseodensification-assisted transcrestal sinus floor elevation (TSFE), and to investigate the impact of sinus width (SW) and sinus angle (SA) on bone augmentation outcomes. Materials and Methods In this randomized controlled trial, 34 patients were randomly allocated to a test group (n = 17) and a control group (n = 17). All patients underwent TSFE assisted by osseodensification drills. Intraoperatively, allogeneic bone collagen (test group) and collagen (control group) were used as a basal layer to protect the sinus membrane. Six months postoperatively, implant stability was evaluated using resonance frequency analysis (RFA) from four directions. Cone-beam computed tomography (CBCT) data were acquired at baseline, immediately postoperatively, and at 6 months to comparatively analyze bone augmentation parameters. Results No sinus membrane perforations occurred during surgery in either group. At 6 months postoperatively, the implant stability quotient (ISQ) values measured from four directions were all above 80 in both groups, with no statistically significant differences between the groups ( P > 0.05). Regarding bone augmentation, the test group demonstrated significantly superior vertical bone gain (VBG) (6.37 ± 1.11 mm) compared to the control group (5.13 ± 0.93 mm; P = 0.001). Although the graft resorption (GR) was slightly lower in the test group (1.51 ± 0.58 mm) compared to the control group (1.95 ± 1.03 mm), the difference was not statistically significant. Furthermore, statistical analysis confirmed no significant correlation between the 6-month bone augmentation outcomes and SW or SA. Conclusions

Research Square
Sichuan University (CN), China-Japan Friendship Hospital (CN)
Good health and well-being
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon