Design and reliability enhancement of an online forward voltage drop monitoring circuit for high-power IGBTs

To address the measurement reliability issues encountered in the online monitoring of the on-state forward voltage drop of high-power IGBTs under complex operating conditions, this work develops an online forward voltage drop monitoring circuit with enhanced measurement reliability for high-power IGBTs. First, to solve the problems of transient overvoltage spikes at the instant of IGBT turn-off, prolonged voltage clamping after turn-off, and insufficient measurement reliability in conventional monitoring circuits, an improved monitoring topology based on MOSFET-controlled commutation is proposed. Key issues, including dead-time-free coordination between the IGBT and MOSFET, suppression of overvoltage at the operational amplifier (OPA) input, the influence of parasitic parameters, and measurement accuracy control, are analyzed and optimized. A state-transition-based reliability analysis is further introduced to evaluate the overall operational reliability of the monitoring circuit under parameter dispersion. The joint Monte Carlo analysis estimates a functional reliability of 93.30% and a safety reliability of 99.958% under the specified parameter variations and state-classification criteria. Furthermore, the designed monitoring circuit is integrated with the gate driver circuit, and experimental validation is carried out on both a converter platform and an equivalent hybrid DC circuit breaker platform. The results show that the proposed scheme can accurately measure the IGBT on-state forward voltage drop during the on-state under different application conditions, demonstrating good versatility. At a representative on-state instant, the relative measurement error is approximately 1.05% compared with a commercial high-voltage probe. During IGBT turn-off, D2 enters reverse blocking and isolates the measurement branch from the power circuit, temporarily suspending measurement until the next on-state. In particular, under strong transient, high-voltage, and high-current operating conditions, the proposed circuit effectively suppresses turn-off transient overvoltage spikes and avoids prolonged voltage clamping, thereby improving measurement accuracy and operational reliability.

Authors

Institutions

Publication Details

Journal
Journal of Engineering and Applied Science
Published
2026-11-18
DOI
https://doi.org/10.1186/s44147-026-01326-7
Primary Topic
Silicon Carbide Semiconductor Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Design and reliability enhancement of an online forward voltage drop monitoring circuit for high-power IGBTs

Xin Liu, Sun Haifeng, Wang Litong, Ziyun Zhao
Journal of Engineering and Applied Science
Silicon Carbide Semiconductor Technologies
article

Design and reliability enhancement of an online forward voltage drop monitoring circuit for high-power IGBTs

Xin Liu, Sun Haifeng, Wang Litong, Ziyun Zhao
article en

Abstract

To address the measurement reliability issues encountered in the online monitoring of the on-state forward voltage drop of high-power IGBTs under complex operating conditions, this work develops an online forward voltage drop monitoring circuit with enhanced measurement reliability for high-power IGBTs. First, to solve the problems of transient overvoltage spikes at the instant of IGBT turn-off, prolonged voltage clamping after turn-off, and insufficient measurement reliability in conventional monitoring circuits, an improved monitoring topology based on MOSFET-controlled commutation is proposed. Key issues, including dead-time-free coordination between the IGBT and MOSFET, suppression of overvoltage at the operational amplifier (OPA) input, the influence of parasitic parameters, and measurement accuracy control, are analyzed and optimized. A state-transition-based reliability analysis is further introduced to evaluate the overall operational reliability of the monitoring circuit under parameter dispersion. The joint Monte Carlo analysis estimates a functional reliability of 93.30% and a safety reliability of 99.958% under the specified parameter variations and state-classification criteria. Furthermore, the designed monitoring circuit is integrated with the gate driver circuit, and experimental validation is carried out on both a converter platform and an equivalent hybrid DC circuit breaker platform. The results show that the proposed scheme can accurately measure the IGBT on-state forward voltage drop during the on-state under different application conditions, demonstrating good versatility. At a representative on-state instant, the relative measurement error is approximately 1.05% compared with a commercial high-voltage probe. During IGBT turn-off, D2 enters reverse blocking and isolates the measurement branch from the power circuit, temporarily suspending measurement until the next on-state. In particular, under strong transient, high-voltage, and high-current operating conditions, the proposed circuit effectively suppresses turn-off transient overvoltage spikes and avoids prolonged voltage clamping, thereby improving measurement accuracy and operational reliability.

Journal of Engineering and Applied ScienceVol. 73(1)
North China Electric Power University (CN)
State Grid Corporation of China, Fundamental Research Funds for the Central Universities, Science and Technology Project of State Grid
Industry, innovation and infrastructure
Silicon Carbide Semiconductor Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon