Design and reliability enhancement of an online forward voltage drop monitoring circuit for high-power IGBTs
To address the measurement reliability issues encountered in the online monitoring of the on-state forward voltage drop of high-power IGBTs under complex operating conditions, this work develops an online forward voltage drop monitoring circuit with enhanced measurement reliability for high-power IGBTs. First, to solve the problems of transient overvoltage spikes at the instant of IGBT turn-off, prolonged voltage clamping after turn-off, and insufficient measurement reliability in conventional monitoring circuits, an improved monitoring topology based on MOSFET-controlled commutation is proposed. Key issues, including dead-time-free coordination between the IGBT and MOSFET, suppression of overvoltage at the operational amplifier (OPA) input, the influence of parasitic parameters, and measurement accuracy control, are analyzed and optimized. A state-transition-based reliability analysis is further introduced to evaluate the overall operational reliability of the monitoring circuit under parameter dispersion. The joint Monte Carlo analysis estimates a functional reliability of 93.30% and a safety reliability of 99.958% under the specified parameter variations and state-classification criteria. Furthermore, the designed monitoring circuit is integrated with the gate driver circuit, and experimental validation is carried out on both a converter platform and an equivalent hybrid DC circuit breaker platform. The results show that the proposed scheme can accurately measure the IGBT on-state forward voltage drop during the on-state under different application conditions, demonstrating good versatility. At a representative on-state instant, the relative measurement error is approximately 1.05% compared with a commercial high-voltage probe. During IGBT turn-off, D2 enters reverse blocking and isolates the measurement branch from the power circuit, temporarily suspending measurement until the next on-state. In particular, under strong transient, high-voltage, and high-current operating conditions, the proposed circuit effectively suppresses turn-off transient overvoltage spikes and avoids prolonged voltage clamping, thereby improving measurement accuracy and operational reliability.
Authors
- Xin Liu (ORCID: https://orcid.org/0000-0001-8323-7289)
- Sun Haifeng
- Wang Litong
- Ziyun Zhao
Institutions
- North China Electric Power University (CN)
Publication Details
- Journal
- Journal of Engineering and Applied Science
- Published
- 2026-11-18
- DOI
- https://doi.org/10.1186/s44147-026-01326-7
- Primary Topic
- Silicon Carbide Semiconductor Technologies
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- State Grid Corporation of China
- Fundamental Research Funds for the Central Universities
- Science and Technology Project of State Grid