Endovascular coiling with Target Tetra® Detachable Coils for small (≤ 5 mm) intracranial aneurysms: a prospective single-center registry study

PURPOSE: Detachable Coil (TTDC) features a tetrahedral configuration designed to facilitate stable coil framing and improve packing stability. Therefore, we prospectively evaluated the safety and efficacy of TTDCs for small IAs. METHODS: In this prospective, single-arm, single-center registry study, patients with small IAs were enrolled between January 2024 and March 2025. Endovascular coiling was performed using TTDCs comprising ≥ 70% of the total coil volume. Primary outcomes were the immediate angiographic occlusion rate and packing density. Secondary outcomes included device-related events, periprocedural complications, and clinical and radiological outcomes at 6 and 12 months. RESULTS: Ninety-five patients with 99 IAs were enrolled, including 98 unruptured IAs and 1 ruptured IA (72.6% female; mean age, 59.5 ± 10.8 years). The technical success rate was 100%. The mean packing density was 32.2 ± 8.7%, with TTDCs comprising 89.5 ± 11.5% of the total coil volume. Wide-neck aneurysms accounted for 98.0% of cases; stent-assisted coiling was used in 34.3%. Device-related events occurred in 7 coils (2.6% of 271 used coils), including failure to load into the microcatheter (n = 5) and difficult retrieval (n = 2). Immediate complete occlusion was achieved in 72.7% of cases and adequate occlusion in 92.9%. At 6 and 12 months, complete occlusion rates were 93.8% and 89.7%, respectively, with no retreatment required. Complications included 1 intraprocedural rupture without sequelae and 2 symptomatic thromboembolic events, one with persistent morbidity at 12 months. There was no procedure-related mortality. CONCLUSIONS: The favorable occlusion rates and acceptable complication profiles suggest that TTDCs are safe and effective for treating small IAs.

Authors

Institutions

Publication Details

Journal
Neuroradiology
Published
2026-11-18
DOI
https://doi.org/10.1007/s00234-026-04247-7
Primary Topic
Intracranial Aneurysms: Treatment and Complications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Endovascular coiling with Target Tetra® Detachable Coils for small (≤ 5 mm) intracranial aneurysms: a prospective single-center registry study

Kyu Seon Chung, Solbi Kim, Keun Young Park, Hyun Jin Han et al.
5 links
Neuroradiology
Intracranial Aneurysms: Treatment and Complications
article

Endovascular coiling with Target Tetra® Detachable Coils for small (≤ 5 mm) intracranial aneurysms: a prospective single-center registry study

Kyu Seon Chung, Solbi Kim, Keun Young Park, Hyun Jin Han, Yong Bae Kim, Jung‐Jae Kim
article en

Abstract

PURPOSE: Detachable Coil (TTDC) features a tetrahedral configuration designed to facilitate stable coil framing and improve packing stability. Therefore, we prospectively evaluated the safety and efficacy of TTDCs for small IAs. METHODS: In this prospective, single-arm, single-center registry study, patients with small IAs were enrolled between January 2024 and March 2025. Endovascular coiling was performed using TTDCs comprising ≥ 70% of the total coil volume. Primary outcomes were the immediate angiographic occlusion rate and packing density. Secondary outcomes included device-related events, periprocedural complications, and clinical and radiological outcomes at 6 and 12 months. RESULTS: Ninety-five patients with 99 IAs were enrolled, including 98 unruptured IAs and 1 ruptured IA (72.6% female; mean age, 59.5 ± 10.8 years). The technical success rate was 100%. The mean packing density was 32.2 ± 8.7%, with TTDCs comprising 89.5 ± 11.5% of the total coil volume. Wide-neck aneurysms accounted for 98.0% of cases; stent-assisted coiling was used in 34.3%. Device-related events occurred in 7 coils (2.6% of 271 used coils), including failure to load into the microcatheter (n = 5) and difficult retrieval (n = 2). Immediate complete occlusion was achieved in 72.7% of cases and adequate occlusion in 92.9%. At 6 and 12 months, complete occlusion rates were 93.8% and 89.7%, respectively, with no retreatment required. Complications included 1 intraprocedural rupture without sequelae and 2 symptomatic thromboembolic events, one with persistent morbidity at 12 months. There was no procedure-related mortality. CONCLUSIONS: The favorable occlusion rates and acceptable complication profiles suggest that TTDCs are safe and effective for treating small IAs.

Neuroradiology
Yonsei University (KR), Severance Hospital (KR), Gangnam Severance Hospital (KR), Yonsei University Health System (KR)
Stryker
Good health and well-being
Intracranial Aneurysms: Treatment and Complications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon