Clinical, Patient, and Operator Evaluation of Intraoral Photogrammetry Versus Conventional Impression in Complete‐Arch Implant Prostheses: A Pilot Randomized Controlled Trial

OBJECTIVES: To compare the passive fit, accuracy discrepancy, patient-reported outcomes, and operator assessment between intraoral photogrammetry (IPG) and conventional impression (CI) for complete-arch implant-supported prostheses. MATERIALS AND METHODS: Patients requiring complete-arch implant-supported prostheses were recruited. Each arch received both IPG and CI and was randomly assigned to one of two groups; a titanium framework was fabricated accordingly. The primary outcome was the passive fit of the framework. Secondary outcomes included accuracy discrepancies (RMS errors, distance errors, angle errors), patient-reported outcomes, and operator assessments. RESULTS: A total of 26 arches (13 in each group) from 17 patients were included. IPG was non-inferior to CI for passive fit score (adjusted between-group difference: 95% CI, -0.74-0.55; p = 0.003), including alternate finger pressure test (0/13 vs. 0/13), Sheffield test (4/13 vs. 5/13), marginal fit with all screws tightened (1/13 vs. 0/13), panoramic radiographic assessment (4/13 vs. 2/13), and screw resistance test (1/13 vs. 2/13). The RMS error, distance deviations, and angle deviation between IPG and CI were 31.50 ± 10.36 μm, 41.90 μm (IQR: 50.00 μm), and 0.19° (IQR: 0.24°), respectively. Patients rated IPG greater comfort (p = 0.035), lower anxiety (p = 0.005), and less nausea (p = 0.017). Operators reported less interference from patient reactions (p = 0.020) and greater fluency (p = 0.035) with IPG. CONCLUSION: Within the limitations of the present study, IPG achieved non-inferior passive fit with CI with clinically acceptable accuracy, superior patient comfort, and fewer operator disturbances, supporting its use as an alternative for complete-arch implant impressions. TRIAL REGISTRATION: ClinicalTrials.gov, NCT07190820.

Authors

Institutions

Publication Details

Journal
Clinical Oral Implants Research
Published
2026-11-18
DOI
https://doi.org/10.1111/clr.70204
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Clinical, Patient, and Operator Evaluation of Intraoral Photogrammetry Versus Conventional Impression in Complete‐Arch Implant Prostheses: A Pilot Randomized Controlled Trial

Hongchang Lai, Junyu Shi, Shujiao Qian, Beilei Liu et al.
4 links
Clinical Oral Implants Research
Dental Implant Techniques and Outcomes
article

Clinical, Patient, and Operator Evaluation of Intraoral Photogrammetry Versus Conventional Impression in Complete‐Arch Implant Prostheses: A Pilot Randomized Controlled Trial

Hongchang Lai, Junyu Shi, Shujiao Qian, Beilei Liu, X J Fu, Zhuo‐Li Huang, Chen Sun
article en

Abstract

OBJECTIVES: To compare the passive fit, accuracy discrepancy, patient-reported outcomes, and operator assessment between intraoral photogrammetry (IPG) and conventional impression (CI) for complete-arch implant-supported prostheses. MATERIALS AND METHODS: Patients requiring complete-arch implant-supported prostheses were recruited. Each arch received both IPG and CI and was randomly assigned to one of two groups; a titanium framework was fabricated accordingly. The primary outcome was the passive fit of the framework. Secondary outcomes included accuracy discrepancies (RMS errors, distance errors, angle errors), patient-reported outcomes, and operator assessments. RESULTS: A total of 26 arches (13 in each group) from 17 patients were included. IPG was non-inferior to CI for passive fit score (adjusted between-group difference: 95% CI, -0.74-0.55; p = 0.003), including alternate finger pressure test (0/13 vs. 0/13), Sheffield test (4/13 vs. 5/13), marginal fit with all screws tightened (1/13 vs. 0/13), panoramic radiographic assessment (4/13 vs. 2/13), and screw resistance test (1/13 vs. 2/13). The RMS error, distance deviations, and angle deviation between IPG and CI were 31.50 ± 10.36 μm, 41.90 μm (IQR: 50.00 μm), and 0.19° (IQR: 0.24°), respectively. Patients rated IPG greater comfort (p = 0.035), lower anxiety (p = 0.005), and less nausea (p = 0.017). Operators reported less interference from patient reactions (p = 0.020) and greater fluency (p = 0.035) with IPG. CONCLUSION: Within the limitations of the present study, IPG achieved non-inferior passive fit with CI with clinically acceptable accuracy, superior patient comfort, and fewer operator disturbances, supporting its use as an alternative for complete-arch implant impressions. TRIAL REGISTRATION: ClinicalTrials.gov, NCT07190820.

Clinical Oral Implants Research
Shanghai Jiao Tong University (CN), Shanghai Ninth People's Hospital (CN)
Shanghai Municipal Health Commission, Shanghai Jiao Tong University, School of Medicine, Shanghai Jiao Tong University
Good health and well-being
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon