Usefulness of an Exoscope-assisted Head-mounted Display for Neurosurgical Assistants in En Bloc Resection of Malignant Skull Base Tumors: A 2-case Report

Exoscopic neurosurgery has become increasingly widespread; however, limitations associated with large external monitors remain, particularly in complex multidisciplinary procedures. To address these issues, we introduced a head-mounted display during exoscopic surgery and evaluated its usefulness from the assistant's perspective in 2 cases. The first case involved a man in his 60s with an intraorbital malignant solitary fibrous tumor who underwent left orbital exenteration for en bloc tumor resection. The second case involved a woman in her 40s with a progressively enlarging intraorbital liposarcoma who underwent the same procedure. In both cases, surgery was performed simultaneously by 2 teams: an endoscopic endonasal approach by the otolaryngology–head and neck surgery team and a transcranial approach by the neurosurgical team. An exoscope (ORBEYE; Olympus, Tokyo, Japan) and head-mounted display (Weaps; Hogy Medical, Tokyo, Japan) were used for visualization, and the duration of head-mounted display use exceeded 2 hours in each case. The head-mounted display enabled the assistant to participate while maintaining an ergonomic upright posture without the need to turn toward an external monitor. Continuous high-resolution visualization directly in front of the eyes facilitated effective assistance, improved understanding of surgical anatomy and workflow, and allowed stable participation throughout the procedure, even in a crowded operative environment. The combined use of a head-mounted display with an exoscope may provide an improved visualization environment for surgical assistants and represents a promising approach to overcome limitations of conventional monitor-based exoscopic surgery.

Authors

Institutions

Publication Details

Journal
NMC Case Report Journal
Published
2026-11-18
DOI
https://doi.org/10.2176/jns-nmc.2026-0134
Primary Topic
Head and Neck Surgical Oncology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Usefulness of an Exoscope-assisted Head-mounted Display for Neurosurgical Assistants in En Bloc Resection of Malignant Skull Base Tumors: A 2-case Report

Takashi Sasayama, Tatsuya Furukawa, Ayako Nakai, Mitsuko Yui et al.
3 links
NMC Case Report Journal
Head and Neck Surgical Oncology
article

Usefulness of an Exoscope-assisted Head-mounted Display for Neurosurgical Assistants in En Bloc Resection of Malignant Skull Base Tumors: A 2-case Report

Takashi Sasayama, Tatsuya Furukawa, Ayako Nakai, Mitsuko Yui, Hirofumi Iwahashi, Ken‐ichi Nibu, Hidehito Kimura, Yusuke Ikeuchi, Akio Yasui, Ayumi HIRANO, Shunsuke SAKAKIBARA
article en

Abstract

Exoscopic neurosurgery has become increasingly widespread; however, limitations associated with large external monitors remain, particularly in complex multidisciplinary procedures. To address these issues, we introduced a head-mounted display during exoscopic surgery and evaluated its usefulness from the assistant's perspective in 2 cases. The first case involved a man in his 60s with an intraorbital malignant solitary fibrous tumor who underwent left orbital exenteration for en bloc tumor resection. The second case involved a woman in her 40s with a progressively enlarging intraorbital liposarcoma who underwent the same procedure. In both cases, surgery was performed simultaneously by 2 teams: an endoscopic endonasal approach by the otolaryngology–head and neck surgery team and a transcranial approach by the neurosurgical team. An exoscope (ORBEYE; Olympus, Tokyo, Japan) and head-mounted display (Weaps; Hogy Medical, Tokyo, Japan) were used for visualization, and the duration of head-mounted display use exceeded 2 hours in each case. The head-mounted display enabled the assistant to participate while maintaining an ergonomic upright posture without the need to turn toward an external monitor. Continuous high-resolution visualization directly in front of the eyes facilitated effective assistance, improved understanding of surgical anatomy and workflow, and allowed stable participation throughout the procedure, even in a crowded operative environment. The combined use of a head-mounted display with an exoscope may provide an improved visualization environment for surgical assistants and represents a promising approach to overcome limitations of conventional monitor-based exoscopic surgery.

NMC Case Report JournalVol. 13(0)
Kobe University (JP)
Good health and well-being
Head and Neck Surgical Oncology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon