Association of type 2 diabetes mellitus with emergence agitation and extubation quality after vitreoretinal surgery: a prospective observational cohort study

Background Emergence agitation and airway responses during extubation may compromise recovery after vitreoretinal surgery. Evidence regarding diabetes is limited. This study aimed to evaluate the association of type 2 diabetes mellitus with emergence agitation and extubation quality after vitreoretinal surgery. Methods In this single-center prospective observational cohort study conducted at a tertiary university hospital in Türkiye, we included 160 adults with American Society of Anesthesiologists (ASA) physical status I–III undergoing vitreoretinal surgery under standardized general anesthesia: 80 with type 2 diabetes and 80 without diabetes. Emergence agitation, defined as a Richmond Agitation-Sedation Scale score ≥ + 1, was assessed immediately after extubation and at 10 minutes. A blinded observer graded extubation quality from 1 (no coughing or straining) to 5 (laryngospasm with severe coughing and labored breathing). Results Immediately after extubation, emergence agitation occurred in 23.8% of patients with diabetes and 12.5% of those without diabetes ( p = 0.065; risk ratio, 1.90; 95% confidence interval, 0.94–3.83). Diabetes was not independently associated with agitation after adjustment for ASA III status and smoking (adjusted odds ratio, 1.90; 95% confidence interval, 0.70–5.19; p = 0.210). Extubation quality was poorer in patients with diabetes (2.0 ± 1.4 versus 1.6 ± 1.1; p = 0.040), and heart rate was higher ( p < 0.001). Glycated hemoglobin, fasting plasma glucose, and diabetes duration were not associated with recovery outcomes. Conclusions Patients with type 2 diabetes had poorer extubation quality and higher perioperative heart rate, whereas an independent association with emergence agitation was not demonstrated. These findings support careful airway and hemodynamic monitoring during emergence.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-18
DOI
https://doi.org/10.21203/rs.3.rs-11260843/v1
Primary Topic
Anesthesia and Sedative Agents
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Association of type 2 diabetes mellitus with emergence agitation and extubation quality after vitreoretinal surgery: a prospective observational cohort study

Erdem Nail Duman, Ali Akdoğan, Aycan BOZ
Research Square
Anesthesia and Sedative Agents
preprint

Association of type 2 diabetes mellitus with emergence agitation and extubation quality after vitreoretinal surgery: a prospective observational cohort study

Erdem Nail Duman, Ali Akdoğan, Aycan BOZ
preprint en

Abstract

Background Emergence agitation and airway responses during extubation may compromise recovery after vitreoretinal surgery. Evidence regarding diabetes is limited. This study aimed to evaluate the association of type 2 diabetes mellitus with emergence agitation and extubation quality after vitreoretinal surgery. Methods In this single-center prospective observational cohort study conducted at a tertiary university hospital in Türkiye, we included 160 adults with American Society of Anesthesiologists (ASA) physical status I–III undergoing vitreoretinal surgery under standardized general anesthesia: 80 with type 2 diabetes and 80 without diabetes. Emergence agitation, defined as a Richmond Agitation-Sedation Scale score ≥ + 1, was assessed immediately after extubation and at 10 minutes. A blinded observer graded extubation quality from 1 (no coughing or straining) to 5 (laryngospasm with severe coughing and labored breathing). Results Immediately after extubation, emergence agitation occurred in 23.8% of patients with diabetes and 12.5% of those without diabetes ( p = 0.065; risk ratio, 1.90; 95% confidence interval, 0.94–3.83). Diabetes was not independently associated with agitation after adjustment for ASA III status and smoking (adjusted odds ratio, 1.90; 95% confidence interval, 0.70–5.19; p = 0.210). Extubation quality was poorer in patients with diabetes (2.0 ± 1.4 versus 1.6 ± 1.1; p = 0.040), and heart rate was higher ( p < 0.001). Glycated hemoglobin, fasting plasma glucose, and diabetes duration were not associated with recovery outcomes. Conclusions Patients with type 2 diabetes had poorer extubation quality and higher perioperative heart rate, whereas an independent association with emergence agitation was not demonstrated. These findings support careful airway and hemodynamic monitoring during emergence.

Research Square
Karadeniz Technical University (TR)
Good health and well-being
Anesthesia and Sedative Agents
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon