Evaluation of a rapid batch export system for electroretinography waveform data

PURPOSE: Accurate application of electroretinography (ERG) remains challenging due to the heterogeneity of retinal disorders. Despite its potential as a diagnostic tool, the clinical use of ERG is limited by the expertise required for interpretation and the error-prone manual extraction of waveform data. At scale, waveform analysis in academic research and clinical trials is made difficult by these challenges. This study performed external validation and quality assessment of automated compared to manual extraction and collection of raw ERG waveforms. METHODS: Raw waveform data was collected using International Society for Clinical Electrophysiology of Vision (ISCEV) standard ERG studies from the ophthalmology practice at Columbia University. A recently developed automated batch exporting tool (Espion, Diagnosys LLC, Lowell, MA) was used to retrieve and compile data and compare with manually collected data for 357 patient sessions. RESULTS: The automated and manually exported data had 99.75% ± 0.17% similarity using a Jaccard similarity test, suggesting the automated tool is both rapid and highly accurate. We identified several inconsistencies leading to errors in the automated batch export. The most common errors in compiled batch exported data included: improperly merging two ERG files taken on the same day and lack of accounting for missing data. CONCLUSIONS: Use of batch export with manual oversight for sources of potential error can allow for faster, more effective data gathering and analysis of large-scale ERG waveform datasets in academic and clinical trial settings.

Authors

Institutions

Publication Details

Journal
Documenta Ophthalmologica
Published
2026-11-19
DOI
https://doi.org/10.1007/s10633-026-10162-2
Primary Topic
Retinal Development and Disorders
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Evaluation of a rapid batch export system for electroretinography waveform data

Stanley Chang, Vlad Diaconita, Scott E. Brodie, Karen Chen et al.
Documenta Ophthalmologica
Retinal Development and Disorders
article

Evaluation of a rapid batch export system for electroretinography waveform data

Stanley Chang, Vlad Diaconita, Scott E. Brodie, Karen Chen, Maria I. Nunez, Aomeng Cui, Leejee Suh, Mia OConnell
article en

Abstract

PURPOSE: Accurate application of electroretinography (ERG) remains challenging due to the heterogeneity of retinal disorders. Despite its potential as a diagnostic tool, the clinical use of ERG is limited by the expertise required for interpretation and the error-prone manual extraction of waveform data. At scale, waveform analysis in academic research and clinical trials is made difficult by these challenges. This study performed external validation and quality assessment of automated compared to manual extraction and collection of raw ERG waveforms. METHODS: Raw waveform data was collected using International Society for Clinical Electrophysiology of Vision (ISCEV) standard ERG studies from the ophthalmology practice at Columbia University. A recently developed automated batch exporting tool (Espion, Diagnosys LLC, Lowell, MA) was used to retrieve and compile data and compare with manually collected data for 357 patient sessions. RESULTS: The automated and manually exported data had 99.75% ± 0.17% similarity using a Jaccard similarity test, suggesting the automated tool is both rapid and highly accurate. We identified several inconsistencies leading to errors in the automated batch export. The most common errors in compiled batch exported data included: improperly merging two ERG files taken on the same day and lack of accounting for missing data. CONCLUSIONS: Use of batch export with manual oversight for sources of potential error can allow for faster, more effective data gathering and analysis of large-scale ERG waveform datasets in academic and clinical trial settings.

Documenta Ophthalmologica
Columbia University Irving Medical Center (US), Columbia University (US)
Research to Prevent Blindness, National Eye Institute
Retinal Development and Disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon