SAP Integrated Encapsulation for Enhanced Fire Resistance of Container Frame Beams

Rapid fire spread and the insufficient durability of conventional passive measures pose critical challenges to the fire safety of container frame structures. This study proposes an innovative active–passive synergetic fire protection system that integrates superabsorbent polymer (SAP) embedded encapsulation (passive) with full-coverage water mist spray (active). The system utilises polypropylene honeycomb panels for SAP storage and an integrated pipeline network for efficient moisture fixation and dynamic replenishment. Key flow velocity parameters for different coverage requirements were optimised via multiphysics simulations and visual tests, validating the feasibility of ‘one-time high-flow-rate filling’ and ‘alternating high/low-flow-rate’ spray schemes. Subsequently, 10 fire performance tests were conducted using a heating programme with a peak temperature similar to that of the hydrocarbon (HC) fire curve. Three spray schemes were evaluated: continuous high-flow-rate spray, one-time high-flow-rate filling, and alternating high/low-flow-rate spray. The results demonstrate that both the continuous high-flow-rate and alternating spray schemes did not reach their fire resistance limits within 60 min, with water consumptions of approximately 21.07 and 6 m3, respectively. Notably, the one-time high-flow-rate filling scheme extended the fire resistance of four-side exposed beams by over 40 min while consuming only 0.15 m3 of water. Furthermore, the dynamic distribution of SAP accumulations was predominantly governed by cross-sectional geometry and fire exposure conditions. Finally, differentiated application recommendations are proposed based on the fire resistance requirements and water resource constraints for various scenarios.

Authors

Institutions

Publication Details

Journal
Fire
Published
2026-11-18
DOI
https://doi.org/10.3390/fire9110517
Primary Topic
Fire effects on concrete materials
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

SAP Integrated Encapsulation for Enhanced Fire Resistance of Container Frame Beams

Guangwei Dai, Liqiang Jiang, Zhuangsu Kang, Zhian Yao et al.
4 links
Fire
Fire effects on concrete materials
article

SAP Integrated Encapsulation for Enhanced Fire Resistance of Container Frame Beams

Guangwei Dai, Liqiang Jiang, Zhuangsu Kang, Zhian Yao, Ning Wu, Wei Chen, Yan Yang, Yue Yang
article en

Abstract

Rapid fire spread and the insufficient durability of conventional passive measures pose critical challenges to the fire safety of container frame structures. This study proposes an innovative active–passive synergetic fire protection system that integrates superabsorbent polymer (SAP) embedded encapsulation (passive) with full-coverage water mist spray (active). The system utilises polypropylene honeycomb panels for SAP storage and an integrated pipeline network for efficient moisture fixation and dynamic replenishment. Key flow velocity parameters for different coverage requirements were optimised via multiphysics simulations and visual tests, validating the feasibility of ‘one-time high-flow-rate filling’ and ‘alternating high/low-flow-rate’ spray schemes. Subsequently, 10 fire performance tests were conducted using a heating programme with a peak temperature similar to that of the hydrocarbon (HC) fire curve. Three spray schemes were evaluated: continuous high-flow-rate spray, one-time high-flow-rate filling, and alternating high/low-flow-rate spray. The results demonstrate that both the continuous high-flow-rate and alternating spray schemes did not reach their fire resistance limits within 60 min, with water consumptions of approximately 21.07 and 6 m3, respectively. Notably, the one-time high-flow-rate filling scheme extended the fire resistance of four-side exposed beams by over 40 min while consuming only 0.15 m3 of water. Furthermore, the dynamic distribution of SAP accumulations was predominantly governed by cross-sectional geometry and fire exposure conditions. Finally, differentiated application recommendations are proposed based on the fire resistance requirements and water resource constraints for various scenarios.

FireVol. 9(11)
Central South University (CN), China University of Mining and Technology (CN), China Railway Major Bridge Reconnaissance & Design Institute (China) (CN), Xuzhou Construction Machinery Group (China) (CN)
National Natural Science Foundation of China
Fire effects on concrete materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon