IMU-Based and Auto-Tuned Virtual Decomposition Control for a Hydraulic Rock-Breaker Boom
Joint encoders of rock-breaker booms sit at exposed pins, where impacts and falling rock damage them. This article controls a hydraulic rock-breaker boom using protected link-mounted inertial measurement units (IMUs) after a one-time calibration. Building on a pairwise complementary filter, each joint observer transports the specific forces of the two adjacent IMUs to the joint point with each link's own gyro rate, so that the joint-angle measurement depends on no estimate. A common Lyapunov function proves the confidence-weighted proportional--integral observer input-to-state stable for arbitrary weight trajectories above a floor, within an explicit error region, and because control errors do not enter the observer, observers and virtual decomposition control (VDC) form a cascade: the boom-joint loops are proved regionally input-to-state stable with the pressure-compensated valves modeled as velocity sources with delays, gain mismatch and dead zones, including online tuning. An auto-tuning procedure identifies each valve's joint assignment, flow gains, dead zones and loop delay through the feedback in use and sets the position gains to satisfy the stability condition. On a 10-t Rambooms X88-540-R boom, the observer deviated from the encoders by 0.07--0.11 degree RMS, and with IMU-only feedback the boom joints tracked a strike-cycle sequence within 0.12--0.21 degree RMS.
Authors
- Mehdi Heydari Shahna (ORCID: https://orcid.org/0000-0002-1310-5392)
- Jouni Mattila (ORCID: https://orcid.org/0000-0003-1799-4323)
- Pauli Mustalahti (ORCID: https://orcid.org/0000-0001-9183-688X)
Institutions
- Tampere University (FI)
Publication Details
- Journal
- Research Square
- Published
- 2026-11-18
- DOI
- https://doi.org/10.21203/rs.3.rs-11737527/v1
- Primary Topic
- Hydraulic and Pneumatic Systems
- Type
- preprint
Funders
- Tekniikan Edistämissäätiö