Second-law analysis of shell-and-tube and double-pipe heat exchangers operating with Al 2 O 3 /water and TiO 2 /water nanofluids: entropy generation and exergy efficiency from experimental data

Experimental studies of nanofluids in heat exchangers usually report only first-law quantities. This study applies a second-law analysis to previously published measurements from a single test facility containing two counterflow exchangers, one of shell-and-tube type and one of double-pipe type, both run with deionized water and with Al 2 O 3 /water and TiO 2 /water nanofluids at 0.1, 0.2 and 0.3 vol.%. The hot stream was supplied at 60°C and 7 L/min, while the cold stream was supplied at 30°C and 5–7 L/min (shell-and-tube) or 2.5–4.5 L/min (double-pipe). Outlet temperatures were reconstructed from the measured heat duties and verified against the reported overall heat transfer coefficients. From these states, the effectiveness, number of transfer units, thermal and frictional entropy generation rates, Bejan number, rate of exergy destruction and second-law efficiency were calculated. In the shell-and-tube exchanger, 0.3 vol.% Al 2 O 3 /water raised the second-law efficiency by 8.4–11.1% and the exergy delivered to the cold stream by 41.6–63.6% relative to water. In the double-pipe exchanger, the corresponding gains were 7.8–9.1% and 37.3–43.2%. Total entropy generation rose with heat duty, but entropy generated per kilowatt transferred fell by up to 4.4%, so the nanofluids transferred more heat with less irreversibility per unit of heat. The Bejan number exceeded 0.999 in all cases, and the estimated pumping penalty was below 1%. Al 2 O 3 /water outperformed TiO 2 /water at every concentration. The larger benefit in the shell-and-tube exchanger is linked to its low-turbulent tube flow, compared with fully turbulent flow in the double-pipe exchanger.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-18
DOI
https://doi.org/10.21203/rs.3.rs-11277907/v1
Primary Topic
Nanofluid Flow and Heat Transfer
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Second-law analysis of shell-and-tube and double-pipe heat exchangers operating with Al 2 O 3 /water and TiO 2 /water nanofluids: entropy generation and exergy efficiency from experimental data

Muhammed Elmnefi
1 links
Research Square
Nanofluid Flow and Heat Transfer
preprint

Second-law analysis of shell-and-tube and double-pipe heat exchangers operating with Al 2 O 3 /water and TiO 2 /water nanofluids: entropy generation and exergy efficiency from experimental data

Muhammed Elmnefi
preprint en

Abstract

Experimental studies of nanofluids in heat exchangers usually report only first-law quantities. This study applies a second-law analysis to previously published measurements from a single test facility containing two counterflow exchangers, one of shell-and-tube type and one of double-pipe type, both run with deionized water and with Al 2 O 3 /water and TiO 2 /water nanofluids at 0.1, 0.2 and 0.3 vol.%. The hot stream was supplied at 60°C and 7 L/min, while the cold stream was supplied at 30°C and 5–7 L/min (shell-and-tube) or 2.5–4.5 L/min (double-pipe). Outlet temperatures were reconstructed from the measured heat duties and verified against the reported overall heat transfer coefficients. From these states, the effectiveness, number of transfer units, thermal and frictional entropy generation rates, Bejan number, rate of exergy destruction and second-law efficiency were calculated. In the shell-and-tube exchanger, 0.3 vol.% Al 2 O 3 /water raised the second-law efficiency by 8.4–11.1% and the exergy delivered to the cold stream by 41.6–63.6% relative to water. In the double-pipe exchanger, the corresponding gains were 7.8–9.1% and 37.3–43.2%. Total entropy generation rose with heat duty, but entropy generated per kilowatt transferred fell by up to 4.4%, so the nanofluids transferred more heat with less irreversibility per unit of heat. The Bejan number exceeded 0.999 in all cases, and the estimated pumping penalty was below 1%. Al 2 O 3 /water outperformed TiO 2 /water at every concentration. The larger benefit in the shell-and-tube exchanger is linked to its low-turbulent tube flow, compared with fully turbulent flow in the double-pipe exchanger.

Research Square
Ostim Technical University (TR)
Affordable and clean energy
Nanofluid Flow and Heat Transfer
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon